GWS6035GD57K
Code: 1977098
Code: 1977098
Material reflector
Without reflector
Mounting method
Pendant
Suitable for number of lamps
6
Lamp type
LED not exchangeable
With light source
Yes
Voltage type
AC
Nominal current
600 - 600mA
With control gear
Yes
Type of control gear
LED operating device current-controlled
Lamp holder
None
Suitable for auxiliary lamp
No
Dimming 0-10 V
No
Dimming potentiometer (integrated)
No
Dimming mains voltage modulation
No
Dimming manufacturer's proprietary system
No
Dimming Sine Wave Reduction
No
Nominal voltage
220 - 240V
Dimming DALI
Yes
Dimming phase cut-on
No
Exchangeable control gear
Yes
Dimming RF
No
Dimming LineSwitch
No
Dimming 1-10 V
No
Dimming phase cut-off
No
Dimming with push-button
No
Lumen maintenance at median useful life of 100,000 hr at 25 °C ambient (tq)
90%
Colour consistency (McAdam ellipse)
SDCM3
Reflector
None
Dimming DSI
No
Dimming Touch and Dim
No
Light distributor
Focal lens
Light sharing
Symmetric/asymmetric
Beam angle
Wide beam 41-80°
No dim function
No
Material housing
Aluminium
Dimming DMX
No
Degree of protection (IP)
IP65
Dimming Zigbee
No
Colour housing
Grey
Luminaire efficacy
118lm/W
Dimming programmable
No
Failure rate at median useful life of 100,000 hrs at 25 °C ambient (tq)
10%
Colour of light
White
Colour rendering index CRI
80-89
Colour temperature
5700 - 5700K
Photobiological safety according to EN 62471
RG0
Constant light output (CLO)
No
Colour temperature adjustable
No
Beam angle adjustable
No
Luminous flux adjustable
Continuously variable
Height/depth
171mm
Length
434mm
Power factor
0.9
Width
376mm
Type of wiring
Ending
Number of poles
5
Connection type
Push-in clamp
With protective cover
No
Conductor cross section
1.5mm²
Max. number of luminaires per miniature circuit breaker B16
8
Max. number of luminaires per miniature circuit breaker C16
13
Operation by Bluetooth
No
Luminaire with limited surface temperature, sign "D“
No
Ball-proof
No
Impact strength
IK07
Protection class
I
Rated ambient temperature according to IEC62722-2-1
-25 - 50°C
Suitable for emergency lighting
No
Max. system power
125W
Emergency power supply integrated
No
Filament test according to IEC 60695-2-11
650 °C - 30 s
Rated luminous flux according to IEC 62722-2-1
14700lm
Zagreb:
0 pcs
Zadar:
0 pcs
GWS6035GD57K
Material reflector
Without reflector
Mounting method
Pendant
Suitable for number of lamps
6
Lamp type
LED not exchangeable
With light source
Voltage type
AC
Nominal current
600 .. 600mA
With control gear
Type of control gear
LED operating device current-controlled
Lamp holder
None
Suitable for auxiliary lamp
Dimming 0-10 V
Dimming potentiometer (integrated)
Dimming mains voltage modulation
Dimming manufacturer's proprietary system
Dimming Sine Wave Reduction
Nominal voltage
220 .. 240V
Dimming DALI
Dimming phase cut-on
Exchangeable control gear
Dimming RF
Dimming LineSwitch
Dimming 1-10 V
Dimming phase cut-off
Dimming with push-button
Lumen maintenance at median useful life of 100,000 hr at 25 °C ambient (tq)
90%
Colour consistency (McAdam ellipse)
SDCM3
Reflector
None
Dimming DSI
Dimming Touch and Dim
Light distributor
Focal lens
Light sharing
Symmetric/asymmetric
Beam angle
Wide beam 41-80°
No dim function
Material housing
Aluminium
Dimming DMX
Degree of protection (IP)
IP65
Dimming Zigbee
Colour housing
Grey
Luminaire efficacy
118lm/W
Dimming programmable
Failure rate at median useful life of 100,000 hrs at 25 °C ambient (tq)
10%
Colour of light
White
Colour rendering index CRI
80-89
Colour temperature
5700 .. 5700K
Photobiological safety according to EN 62471
RG0
Constant light output (CLO)
Colour temperature adjustable
No
Beam angle adjustable
No
Luminous flux adjustable
Continuously variable
Height/depth
171mm
Length
434mm
Power factor
0.9
Width
376mm
Type of wiring
Ending
Number of poles
5
Connection type
Push-in clamp
With protective cover
Conductor cross section
1.5mm²
Max. number of luminaires per miniature circuit breaker B16
8
Max. number of luminaires per miniature circuit breaker C16
13
Operation by Bluetooth
Luminaire with limited surface temperature, sign "D“
Ball-proof
Impact strength
IK07
Protection class
I
Rated ambient temperature according to IEC62722-2-1
-25 .. 50°C
Suitable for emergency lighting
Max. system power
125W
Emergency power supply integrated
Filament test according to IEC 60695-2-11
650 °C - 30 s
Rated luminous flux according to IEC 62722-2-1
14700lm
We use cookies to enhance your experience.