Details
- Luminaires
- High bay luminaire
- 1 KOM
- GEWISS
Technical specifications
With light source
Yes
Lamp type
LED not exchangeable
Mounting method
Pendant
Lamp holder
None
Voltage type
AC
Suitable for number of lamps
2
Nominal voltage
220 - 240V
Nominal current
330 - 330mA
Material housing
Plastic
Dimming 1-10 V
No
Exchangeable control gear
Yes
Dimming DMX
No
Dimming DALI
Yes
Dimming LineSwitch
No
Dimming potentiometer (integrated)
No
Dimming phase cut-on
No
Dimming DSI
No
Dimming manufacturer's proprietary system
No
Dimming Sine Wave Reduction
No
Type of control gear
LED operating device current-controlled
Dimming Touch and Dim
No
With control gear
Yes
Dimming with push-button
No
Dimming Zigbee
No
Dimming phase cut-off
No
Light distributor
Reflector
Suitable for auxiliary lamp
No
Reflector
High-gloss
Dimming programmable
No
Reflector colour
Silver
Colour housing
Grey
Lumen maintenance at median useful life of 100,000 hr at 25 °C ambient (tq)
90%
Failure rate at median useful life of 100,000 hrs at 25 °C ambient (tq)
10%
Protection class
I
Rated ambient temperature according to IEC62722-2-1
-30 - 50°C
Dimming 0-10 V
No
Beam angle
Extreme wide beam >80°
Light sharing
Symmetric
No dim function
No
Dimming RF
No
Colour consistency (McAdam ellipse)
SDCM3
Ball-proof
No
Impact strength
IK07
Luminaire with limited surface temperature, sign "D“
Yes
Material reflector
Plastic
Dimming mains voltage modulation
No
Degree of protection (IP)
IP65
Max. system power
125W
Rated luminous flux according to IEC 62722-2-1
19800lm
Colour of light
White
Colour temperature
4000 - 4000K
Colour rendering index CRI
80-89
Photobiological safety according to EN 62471
RG0
Power factor
0.9
Luminaire efficacy
158lm/W
Constant light output (CLO)
No
Colour temperature adjustable
No
Luminous flux adjustable
Continuously variable
Length
700mm
Beam angle adjustable
No
Height/depth
113mm
Width
254mm
Type of wiring
Ending
Number of poles
5
Conductor cross section
1.5mm²
Connection type
Push-in clamp
With protective cover
Yes
Max. number of luminaires per miniature circuit breaker B16
7
Operation by Bluetooth
No
Max. number of luminaires per miniature circuit breaker C16
11
Emergency power supply integrated
No
Filament test according to IEC 60695-2-11
650 °C - 30 s
Suitable for emergency lighting
No
From same serie
MV97113

Details
- Luminaires
- High bay luminaire
- 1 KOM
- GEWISS
Technical specifications
With light source
Lamp type
LED not exchangeable
Mounting method
Pendant
Lamp holder
None
Voltage type
AC
Suitable for number of lamps
2
Nominal voltage
220 .. 240V
Nominal current
330 .. 330mA
Material housing
Plastic
Dimming 1-10 V
Exchangeable control gear
Dimming DMX
Dimming DALI
Dimming LineSwitch
Dimming potentiometer (integrated)
Dimming phase cut-on
Dimming DSI
Dimming manufacturer's proprietary system
Dimming Sine Wave Reduction
Type of control gear
LED operating device current-controlled
Dimming Touch and Dim
With control gear
Dimming with push-button
Dimming Zigbee
Dimming phase cut-off
Light distributor
Reflector
Suitable for auxiliary lamp
Reflector
High-gloss
Dimming programmable
Reflector colour
Silver
Colour housing
Grey
Lumen maintenance at median useful life of 100,000 hr at 25 °C ambient (tq)
90%
Failure rate at median useful life of 100,000 hrs at 25 °C ambient (tq)
10%
Protection class
I
Rated ambient temperature according to IEC62722-2-1
-30 .. 50°C
Dimming 0-10 V
Beam angle
Extreme wide beam >80°
Light sharing
Symmetric
No dim function
Dimming RF
Colour consistency (McAdam ellipse)
SDCM3
Ball-proof
Impact strength
IK07
Luminaire with limited surface temperature, sign "D“
Material reflector
Plastic
Dimming mains voltage modulation
Degree of protection (IP)
IP65
Max. system power
125W
Rated luminous flux according to IEC 62722-2-1
19800lm
Colour of light
White
Colour temperature
4000 .. 4000K
Colour rendering index CRI
80-89
Photobiological safety according to EN 62471
RG0
Power factor
0.9
Luminaire efficacy
158lm/W
Constant light output (CLO)
Colour temperature adjustable
No
Luminous flux adjustable
Continuously variable
Length
700mm
Beam angle adjustable
No
Height/depth
113mm
Width
254mm
Type of wiring
Ending
Number of poles
5
Conductor cross section
1.5mm²
Connection type
Push-in clamp
With protective cover
Max. number of luminaires per miniature circuit breaker B16
7
Operation by Bluetooth
Max. number of luminaires per miniature circuit breaker C16
11
Emergency power supply integrated
Filament test according to IEC 60695-2-11
650 °C - 30 s
Suitable for emergency lighting
From same serie
We use cookies to enhance your experience.