Aleta.hr
Main Product Image

GWD7214

Code: 1966971

ManufacturerRAZNO
Catalog numberGWD7214
Type
EAN code8011564328679

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Degree of protection (IP)

IP20

Type of control element

Rocker lever

Number of poles

4

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

125A

Motor drive optional

Yes

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

0

Rated voltage

690 - 690V

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

No

Overload release current setting

87.5 - 125A

Suitable for DIN rail (top hat rail) mounting

No

Adjustment range undelayed short-circuit release

1250 - 1250A

With switched-off indicator

Yes

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Yes

Complete device with protection unit

Yes

Integrated earth fault protection

No

With under voltage release

No

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GWD7214

Main Product Image

Details

  • Low-voltage industrial components
  • Power circuit-breaker for trafo/generator/installation protection
  • 1 KOM
  • GEWISS

Technical specifications

Degree of protection (IP)

IP20

Type of control element

Rocker lever

Number of poles

4

Number of auxiliary contacts as normally open contact

0

Number of auxiliary contacts as normally closed contact

0

Rated permanent current Iu

125A

Motor drive optional

Device construction

Built-in device fixed built-in technique

Number of auxiliary contacts as change-over contact

0

Rated voltage

690 .. 690V

Type of electrical connection of main circuit

Bolt connection

Motor drive integrated

Overload release current setting

87.5 .. 125A

Suitable for DIN rail (top hat rail) mounting

Adjustment range undelayed short-circuit release

1250 .. 1250A

With switched-off indicator

Position of connection for main current circuit

Front side

DIN rail (top hat rail) mounting optional

Complete device with protection unit

Integrated earth fault protection

With under voltage release

Rated short-circuit breaking capacity lcu at 400 V, 50 Hz

36kA