Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Over voltage category

3

Rated voltage

230V

Ambient temperature during operating

-25 - 40°C

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Built-in depth

72mm

Rated current

4.9A

Anti-nuisance tripping version

No

With interlocking device

No

Concurrently switching neutral conductor

No

Pollution degree

2

Number of protected poles

2

Rated short-circuit breaking capacity according to EN 61009

10kA

Voltage type

AC

Frequency

50/60 Hz

Flush-mounted installation

No

Connectable conductor cross section multi-wired

35 - 35mm²

Rated fault current

0.03A

Rated insulation voltage Ui

500V

Current limiting class

3

Leakage current type

A

Surge current capacity

0.25kA

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Connectable conductor cross section solid-core

35 - 35mm²

Power loss

13W


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW95331

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Disconnection characteristic

Undelayed

Release characteristic

B

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Over voltage category

3

Rated voltage

230V

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Built-in depth

72mm

Rated current

4.9A

Anti-nuisance tripping version

With interlocking device

Concurrently switching neutral conductor

Pollution degree

2

Number of protected poles

2

Rated short-circuit breaking capacity according to EN 61009

10kA

Voltage type

AC

Frequency

50/60 Hz

Flush-mounted installation

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated fault current

0.03A

Rated insulation voltage Ui

500V

Current limiting class

3

Leakage current type

A

Surge current capacity

0.25kA

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Connectable conductor cross section solid-core

35 .. 35mm²

Power loss

13W

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.