Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Disconnection characteristic

Undelayed

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.3A

Rated current

11.52A

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated voltage

400V

Release characteristic

B

Frequency

50/60 Hz

Over voltage category

3

Ambient temperature during operating

-25 - 40°C

Current limiting class

1

Pollution degree

2

With interlocking device

No

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Concurrently switching neutral conductor

No

Power loss

25W

Leakage current type

A

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Built-in depth

72mm

Rated short-circuit breaking capacity according to EN 61009

6kA

Flush-mounted installation

No

Number of protected poles

4

Anti-nuisance tripping version

No

Voltage type

AC

Connectable conductor cross section multi-wired

35 - 35mm²

Connectable conductor cross section solid-core

35 - 35mm²


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW95179

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Disconnection characteristic

Undelayed

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.3A

Rated current

11.52A

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated voltage

400V

Release characteristic

B

Frequency

50/60 Hz

Over voltage category

3

Ambient temperature during operating

-25 .. 40°C

Current limiting class

1

Pollution degree

2

With interlocking device

Width in number of modular spacings

4

Degree of protection (IP)

IP20

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Concurrently switching neutral conductor

Power loss

25W

Leakage current type

A

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Built-in depth

72mm

Rated short-circuit breaking capacity according to EN 61009

6kA

Flush-mounted installation

Number of protected poles

4

Anti-nuisance tripping version

Voltage type

AC

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.