Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

400V

Leakage current type

A

Number of protected poles

3

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

8.16A

Number of poles (total)

3

Current limiting class

1

Rated fault current

0.3A

Concurrently switching neutral conductor

No

With interlocking device

No

Voltage type

AC

Built-in depth

72mm

Pollution degree

2

Ambient temperature during operating

-25 - 40°C

Disconnection characteristic

Undelayed

Connectable conductor cross section solid-core

35 - 35mm²

Power loss

20W

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Release characteristic

B

Surge current capacity

0.25kA

Flush-mounted installation

No

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

35 - 35mm²

Anti-nuisance tripping version

No

Degree of protection (IP)

IP20

Over voltage category

3

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Frequency

50/60 Hz


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW95158

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

400V

Leakage current type

A

Number of protected poles

3

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

8.16A

Number of poles (total)

3

Current limiting class

1

Rated fault current

0.3A

Concurrently switching neutral conductor

With interlocking device

Voltage type

AC

Built-in depth

72mm

Pollution degree

2

Ambient temperature during operating

-25 .. 40°C

Disconnection characteristic

Undelayed

Connectable conductor cross section solid-core

35 .. 35mm²

Power loss

20W

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Release characteristic

B

Surge current capacity

0.25kA

Flush-mounted installation

Width in number of modular spacings

3

Connectable conductor cross section multi-wired

35 .. 35mm²

Anti-nuisance tripping version

Degree of protection (IP)

IP20

Over voltage category

3

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Frequency

50/60 Hz

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.