  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated insulation voltage Ui

500V

Rated fault current

0.03A

Power loss

10W

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Leakage current type

A

Number of poles (total)

2

Rated current

4.12A

With interlocking device

No

Rated short-circuit breaking capacity according to EN 61009

6kA

Ambient temperature during operating

-25 - 40°C

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Number of protected poles

2

Over voltage category

3

Rated voltage

230V

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

No

Current limiting class

3

Pollution degree

2

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Release characteristic

B

Built-in depth

72mm

Disconnection characteristic

Undelayed

Connectable conductor cross section multi-wired

35 - 35mm²

Flush-mounted installation

No

Voltage type

AC

Concurrently switching neutral conductor

No

Connectable conductor cross section solid-core

35 - 35mm²

Frequency

50/60 Hz

Surge current capacity

0.25kA


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW95126

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated insulation voltage Ui

500V

Rated fault current

0.03A

Power loss

10W

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Leakage current type

A

Number of poles (total)

2

Rated current

4.12A

With interlocking device

Rated short-circuit breaking capacity according to EN 61009

6kA

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Number of protected poles

2

Over voltage category

3

Rated voltage

230V

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

Current limiting class

3

Pollution degree

2

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Release characteristic

B

Built-in depth

72mm

Disconnection characteristic

Undelayed

Connectable conductor cross section multi-wired

35 .. 35mm²

Flush-mounted installation

Voltage type

AC

Concurrently switching neutral conductor

Connectable conductor cross section solid-core

35 .. 35mm²

Frequency

50/60 Hz

Surge current capacity

0.25kA