Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of protected poles

2

Number of poles (total)

2

Rated current

2.12A

Leakage current type

A

Rated insulation voltage Ui

500V

Rated fault current

0.1A

Power loss

6W

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Release characteristic

C

Disconnection characteristic

Undelayed

Concurrently switching neutral conductor

No

Ambient temperature during operating

-25 - 40°C

Rated voltage

230V

Pollution degree

2

With interlocking device

No

Width in number of modular spacings

2

Voltage type

AC

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

No

Over voltage category

3

Surge current capacity

0.25kA

Current limiting class

3

Frequency

50/60 Hz

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Built-in depth

72mm

Flush-mounted installation

No

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 - 35mm²

Connectable conductor cross section multi-wired

35 - 35mm²


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW95785

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of protected poles

2

Number of poles (total)

2

Rated current

2.12A

Leakage current type

A

Rated insulation voltage Ui

500V

Rated fault current

0.1A

Power loss

6W

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Release characteristic

C

Disconnection characteristic

Undelayed

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 40°C

Rated voltage

230V

Pollution degree

2

With interlocking device

Width in number of modular spacings

2

Voltage type

AC

Rated impulse withstand voltage Uimp

4kV

Anti-nuisance tripping version

Over voltage category

3

Surge current capacity

0.25kA

Current limiting class

3

Frequency

50/60 Hz

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Built-in depth

72mm

Flush-mounted installation

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.