Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

110V

Number of protected poles

2

Number of poles (total)

2

Rated insulation voltage Ui

500V

Rated fault current

0.03A

Frequency

50/60 Hz

Leakage current type

AC

Concurrently switching neutral conductor

No

With interlocking device

No

Over voltage category

3

Rated current

5.44A

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Surge current capacity

0.25kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Voltage type

AC

Power loss

20W

Disconnection characteristic

Undelayed

Release characteristic

C

Built-in depth

72mm

Anti-nuisance tripping version

No

Ambient temperature during operating

-25 - 40°C

Width in number of modular spacings

2

Connectable conductor cross section multi-wired

35 - 35mm²

Pollution degree

2

Connectable conductor cross section solid-core

35 - 35mm²

Degree of protection (IP)

IP20

Flush-mounted installation

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW95028MA

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

110V

Number of protected poles

2

Number of poles (total)

2

Rated insulation voltage Ui

500V

Rated fault current

0.03A

Frequency

50/60 Hz

Leakage current type

AC

Concurrently switching neutral conductor

With interlocking device

Over voltage category

3

Rated current

5.44A

Rated impulse withstand voltage Uimp

4kV

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Surge current capacity

0.25kA

Rated short-circuit breaking capacity according to EN 61009

10kA

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Voltage type

AC

Power loss

20W

Disconnection characteristic

Undelayed

Release characteristic

C

Built-in depth

72mm

Anti-nuisance tripping version

Ambient temperature during operating

-25 .. 40°C

Width in number of modular spacings

2

Connectable conductor cross section multi-wired

35 .. 35mm²

Pollution degree

2

Connectable conductor cross section solid-core

35 .. 35mm²

Degree of protection (IP)

IP20

Flush-mounted installation

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.