Aleta.hr
Main Product Image

GW95025MA

Code: 1966067

ManufacturerRAZNO
Catalog numberGW95025MA
Type
EAN code8011564540279

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

110V

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Number of protected poles

2

Rated current

6A

Power loss

6W

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Current limiting class

3

Leakage current type

AC

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Surge current capacity

0.25kA

Release characteristic

C

Voltage type

AC

Rated fault current

0.03A

Rated short-circuit breaking capacity according to EN 61009

10kA

Concurrently switching neutral conductor

No

Ambient temperature during operating

-25 - 40°C

With interlocking device

No

Frequency

50/60 Hz

Anti-nuisance tripping version

No

Width in number of modular spacings

2

Flush-mounted installation

No

Built-in depth

72mm

Pollution degree

2

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 - 35mm²

Over voltage category

3

Connectable conductor cross section multi-wired

35 - 35mm²


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW95025MA

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

110V

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Number of protected poles

2

Rated current

6A

Power loss

6W

Rated short-circuit breaking capacity according to IEC 60947-2

15kA

Current limiting class

3

Leakage current type

AC

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

10kA

Surge current capacity

0.25kA

Release characteristic

C

Voltage type

AC

Rated fault current

0.03A

Rated short-circuit breaking capacity according to EN 61009

10kA

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Frequency

50/60 Hz

Anti-nuisance tripping version

Width in number of modular spacings

2

Flush-mounted installation

Built-in depth

72mm

Pollution degree

2

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

Over voltage category

3

Connectable conductor cross section multi-wired

35 .. 35mm²

From same serie