Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

230V

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

2

Leakage current type

A

Rated insulation voltage Ui

500V

Rated fault current

0.3A

Current limiting class

3

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Surge current capacity

3kA

Rated current

5.44A

Concurrently switching neutral conductor

No

Power loss

20W

Rated short-circuit breaking capacity according to EN 61009

6kA

Voltage type

AC

Disconnection characteristic

Selective

Release characteristic

C

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Over voltage category

3

Frequency

50/60 Hz

With interlocking device

No

Ambient temperature during operating

-25 - 40°C

Anti-nuisance tripping version

Yes

Width in number of modular spacings

2

Flush-mounted installation

No

Connectable conductor cross section solid-core

35 - 35mm²

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 - 35mm²

Pollution degree

2

Number of protected poles

2

Built-in depth

72mm


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW95848

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

230V

Rated impulse withstand voltage Uimp

4kV

Number of poles (total)

2

Leakage current type

A

Rated insulation voltage Ui

500V

Rated fault current

0.3A

Current limiting class

3

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Surge current capacity

3kA

Rated current

5.44A

Concurrently switching neutral conductor

Power loss

20W

Rated short-circuit breaking capacity according to EN 61009

6kA

Voltage type

AC

Disconnection characteristic

Selective

Release characteristic

C

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Over voltage category

3

Frequency

50/60 Hz

With interlocking device

Ambient temperature during operating

-25 .. 40°C

Anti-nuisance tripping version

Width in number of modular spacings

2

Flush-mounted installation

Connectable conductor cross section solid-core

35 .. 35mm²

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 .. 35mm²

Pollution degree

2

Number of protected poles

2

Built-in depth

72mm