Code: 1966016

ManufacturerRAZNO
Catalog numberGW94339
Type
EAN code8011564280083

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of protected poles

2

Number of poles (total)

2

Rated voltage

230V

Rated current

5.76A

Leakage current type

A

Rated insulation voltage Ui

500V

Current limiting class

3

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.3A

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Voltage type

AC

Surge current capacity

0.25kA

Frequency

50/60 Hz

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Release characteristic

C

Concurrently switching neutral conductor

No

Pollution degree

2

Ambient temperature during operating

-25 - 40°C

Power loss

25W

Built-in depth

72mm

Width in number of modular spacings

2

Rated short-circuit breaking capacity according to EN 61009

6kA

Connectable conductor cross section multi-wired

35 - 35mm²

Anti-nuisance tripping version

No

Connectable conductor cross section solid-core

35 - 35mm²

Degree of protection (IP)

IP20

Flush-mounted installation

No

With interlocking device

No

Over voltage category

3


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW94339

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of protected poles

2

Number of poles (total)

2

Rated voltage

230V

Rated current

5.76A

Leakage current type

A

Rated insulation voltage Ui

500V

Current limiting class

3

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.3A

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Voltage type

AC

Surge current capacity

0.25kA

Frequency

50/60 Hz

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Release characteristic

C

Concurrently switching neutral conductor

Pollution degree

2

Ambient temperature during operating

-25 .. 40°C

Power loss

25W

Built-in depth

72mm

Width in number of modular spacings

2

Rated short-circuit breaking capacity according to EN 61009

6kA

Connectable conductor cross section multi-wired

35 .. 35mm²

Anti-nuisance tripping version

Connectable conductor cross section solid-core

35 .. 35mm²

Degree of protection (IP)

IP20

Flush-mounted installation

With interlocking device

Over voltage category

3

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.