Aleta.hr
Main Product Image

GW94117

Code: 1965940

ManufacturerRAZNO
Catalog numberGW94117
Type
EAN code8011564384446

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

230V

Number of poles (total)

2

Number of protected poles

1

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

16A

Current limiting class

3

Rated short-circuit breaking capacity according to EN 61009

6kA

Leakage current type

AC

Power loss

16W

Rated fault current

0.3A

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Voltage type

AC

Surge current capacity

0.25kA

Release characteristic

C

With interlocking device

No

Over voltage category

3

Frequency

50/60 Hz

Concurrently switching neutral conductor

Yes

Built-in depth

72mm

Ambient temperature during operating

-25 - 40°C

Width in number of modular spacings

2

Pollution degree

2

Degree of protection (IP)

IP20

Anti-nuisance tripping version

No

Flush-mounted installation

No

Connectable conductor cross section solid-core

35 - 35mm²

Connectable conductor cross section multi-wired

35 - 35mm²


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW94117

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

230V

Number of poles (total)

2

Number of protected poles

1

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated current

16A

Current limiting class

3

Rated short-circuit breaking capacity according to EN 61009

6kA

Leakage current type

AC

Power loss

16W

Rated fault current

0.3A

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Voltage type

AC

Surge current capacity

0.25kA

Release characteristic

C

With interlocking device

Over voltage category

3

Frequency

50/60 Hz

Concurrently switching neutral conductor

Built-in depth

72mm

Ambient temperature during operating

-25 .. 40°C

Width in number of modular spacings

2

Pollution degree

2

Degree of protection (IP)

IP20

Anti-nuisance tripping version

Flush-mounted installation

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.