Technical specifications

Number of poles (total)

4

Rated voltage

400V

Rated short-circuit breaking capacity according to IEC 60947-2

4.5kA

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Flush-mounted installation

No

Built-in depth

72mm

Release characteristic

C

Voltage type

AC

Degree of protection (IP)

IP20

Anti-nuisance tripping version

No

Rated current

11.52A

Current limiting class

1

Rated fault current

0.03A

Power loss

25W

Concurrently switching neutral conductor

No

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Number of protected poles

4

Over voltage category

3

Connectable conductor cross section solid-core

35 - 35mm²

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 - 40°C

With interlocking device

No

Pollution degree

2

Disconnection characteristic

Undelayed

Connectable conductor cross section multi-wired

35 - 35mm²

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Width in number of modular spacings

4

Leakage current type

A

Frequency

50/60 Hz


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW94269

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

4

Rated voltage

400V

Rated short-circuit breaking capacity according to IEC 60947-2

4.5kA

Surge current capacity

0.25kA

Rated insulation voltage Ui

500V

Flush-mounted installation

Built-in depth

72mm

Release characteristic

C

Voltage type

AC

Degree of protection (IP)

IP20

Anti-nuisance tripping version

Rated current

11.52A

Current limiting class

1

Rated fault current

0.03A

Power loss

25W

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Number of protected poles

4

Over voltage category

3

Connectable conductor cross section solid-core

35 .. 35mm²

Rated impulse withstand voltage Uimp

4kV

Ambient temperature during operating

-25 .. 40°C

With interlocking device

Pollution degree

2

Disconnection characteristic

Undelayed

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Width in number of modular spacings

4

Leakage current type

A

Frequency

50/60 Hz

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.