Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Leakage current type

A

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Voltage type

AC

Surge current capacity

0.25kA

Frequency

50/60 Hz

Built-in depth

72mm

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Over voltage category

3

Ambient temperature during operating

-25 - 40°C

Rated current

4.56A

Current limiting class

3

Flush-mounted installation

No

Number of protected poles

2

Rated insulation voltage Ui

500V

Rated voltage

230V

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Rated fault current

0.03A

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Disconnection characteristic

Undelayed

Power loss

16W

Release characteristic

C

Concurrently switching neutral conductor

No

With interlocking device

No

Connectable conductor cross section solid-core

35 - 35mm²

Connectable conductor cross section multi-wired

35 - 35mm²

Pollution degree

2

Anti-nuisance tripping version

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW94227

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated impulse withstand voltage Uimp

4kV

Leakage current type

A

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Voltage type

AC

Surge current capacity

0.25kA

Frequency

50/60 Hz

Built-in depth

72mm

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Over voltage category

3

Ambient temperature during operating

-25 .. 40°C

Rated current

4.56A

Current limiting class

3

Flush-mounted installation

Number of protected poles

2

Rated insulation voltage Ui

500V

Rated voltage

230V

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Rated fault current

0.03A

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Disconnection characteristic

Undelayed

Power loss

16W

Release characteristic

C

Concurrently switching neutral conductor

With interlocking device

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Pollution degree

2

Anti-nuisance tripping version

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.