Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated insulation voltage Ui

500V

Rated voltage

230V

Rated fault current

0.03A

Number of poles (total)

2

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

With interlocking device

No

Frequency

50/60 Hz

Current limiting class

3

Disconnection characteristic

Undelayed

Surge current capacity

0.25kA

Release characteristic

C

Concurrently switching neutral conductor

Yes

Over voltage category

3

Pollution degree

2

Leakage current type

A

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Power loss

32W

Rated current

6.33A

Ambient temperature during operating

-25 - 40°C

Anti-nuisance tripping version

No

Flush-mounted installation

No

Connectable conductor cross section solid-core

35 - 35mm²

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Connectable conductor cross section multi-wired

35 - 35mm²

Built-in depth

72mm


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW94210

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated insulation voltage Ui

500V

Rated voltage

230V

Rated fault current

0.03A

Number of poles (total)

2

Number of protected poles

1

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

With interlocking device

Frequency

50/60 Hz

Current limiting class

3

Disconnection characteristic

Undelayed

Surge current capacity

0.25kA

Release characteristic

C

Concurrently switching neutral conductor

Over voltage category

3

Pollution degree

2

Leakage current type

A

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Power loss

32W

Rated current

6.33A

Ambient temperature during operating

-25 .. 40°C

Anti-nuisance tripping version

Flush-mounted installation

Connectable conductor cross section solid-core

35 .. 35mm²

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Connectable conductor cross section multi-wired

35 .. 35mm²

Built-in depth

72mm

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.