Aleta.hr

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

3

Rated fault current

0.3A

Current limiting class

1

Number of protected poles

3

Voltage type

AC

Power loss

32W

Frequency

50/60 Hz

Disconnection characteristic

Undelayed

Rated current

11.01A

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Rated voltage

400V

Pollution degree

2

Connectable conductor cross section multi-wired

35 - 35mm²

Degree of protection (IP)

IP20

Over voltage category

3

Built-in depth

72mm

Ambient temperature during operating

-25 - 40°C

Release characteristic

C

Leakage current type

AC

Surge current capacity

0.25kA

Rated impulse withstand voltage Uimp

4kV

Width in number of modular spacings

3

Anti-nuisance tripping version

No

Concurrently switching neutral conductor

No

Flush-mounted installation

No

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity according to IEC 60947-2

4.5kA

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Connectable conductor cross section solid-core

35 - 35mm²

With interlocking device

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW94060

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

3

Rated fault current

0.3A

Current limiting class

1

Number of protected poles

3

Voltage type

AC

Power loss

32W

Frequency

50/60 Hz

Disconnection characteristic

Undelayed

Rated current

11.01A

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Rated voltage

400V

Pollution degree

2

Connectable conductor cross section multi-wired

35 .. 35mm²

Degree of protection (IP)

IP20

Over voltage category

3

Built-in depth

72mm

Ambient temperature during operating

-25 .. 40°C

Release characteristic

C

Leakage current type

AC

Surge current capacity

0.25kA

Rated impulse withstand voltage Uimp

4kV

Width in number of modular spacings

3

Anti-nuisance tripping version

Concurrently switching neutral conductor

Flush-mounted installation

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity according to IEC 60947-2

4.5kA

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Connectable conductor cross section solid-core

35 .. 35mm²

With interlocking device

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.