Aleta.hr
Main Product Image

GW94017

Code: 1965836

ManufacturerRAZNO
Catalog numberGW94017
Type
EAN code8011564668881

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Number of protected poles

1

Leakage current type

AC

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Rated fault current

0.3A

Rated current

2.95A

Rated voltage

230V

Current limiting class

3

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Power loss

16W

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Surge current capacity

0.25kA

Voltage type

AC

With interlocking device

No

Pollution degree

2

Concurrently switching neutral conductor

Yes

Anti-nuisance tripping version

No

Flush-mounted installation

No

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 - 40°C

Frequency

50/60 Hz

Over voltage category

3

Connectable conductor cross section multi-wired

35 - 35mm²

Release characteristic

C

Connectable conductor cross section solid-core

35 - 35mm²

Width in number of modular spacings

2

Built-in depth

72mm


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW94017

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Number of protected poles

1

Leakage current type

AC

Rated short-circuit breaking capacity according to EN 61009

4.5kA

Rated fault current

0.3A

Rated current

2.95A

Rated voltage

230V

Current limiting class

3

Disconnection characteristic

Undelayed

Rated short-circuit breaking capacity Icn according to EN 61009-1

4.5kA

Rated impulse withstand voltage Uimp

4kV

Rated insulation voltage Ui

500V

Power loss

16W

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Surge current capacity

0.25kA

Voltage type

AC

With interlocking device

Pollution degree

2

Concurrently switching neutral conductor

Anti-nuisance tripping version

Flush-mounted installation

Degree of protection (IP)

IP20

Ambient temperature during operating

-25 .. 40°C

Frequency

50/60 Hz

Over voltage category

3

Connectable conductor cross section multi-wired

35 .. 35mm²

Release characteristic

C

Connectable conductor cross section solid-core

35 .. 35mm²

Width in number of modular spacings

2

Built-in depth

72mm

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.