  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated insulation voltage Ui

500V

Leakage current type

Other

Current limiting class

3

Disconnection characteristic

Short-time delayed

Rated voltage

230V

Power loss

13W

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Frequency

50/60 Hz

Concurrently switching neutral conductor

No

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Release characteristic

B

Pollution degree

2

Rated current

4.9A

With interlocking device

No

Over voltage category

3

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated fault current

0.3A

Number of protected poles

2

Number of poles (total)

2

Built-in depth

72mm

Flush-mounted installation

No

Ambient temperature during operating

-25 - 40°C

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 - 35mm²

Anti-nuisance tripping version

Yes

Width in number of modular spacings

2

Connectable conductor cross section solid-core

35 - 35mm²


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW95981

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated insulation voltage Ui

500V

Leakage current type

Other

Current limiting class

3

Disconnection characteristic

Short-time delayed

Rated voltage

230V

Power loss

13W

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Frequency

50/60 Hz

Concurrently switching neutral conductor

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Release characteristic

B

Pollution degree

2

Rated current

4.9A

With interlocking device

Over voltage category

3

Rated short-circuit breaking capacity according to IEC 60947-2

10kA

Rated short-circuit breaking capacity according to EN 61009

6kA

Rated fault current

0.3A

Number of protected poles

2

Number of poles (total)

2

Built-in depth

72mm

Flush-mounted installation

Ambient temperature during operating

-25 .. 40°C

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 .. 35mm²

Anti-nuisance tripping version

Width in number of modular spacings

2

Connectable conductor cross section solid-core

35 .. 35mm²

From same serie