Aleta.hr
Main Product Image

GW95940

Code: 1965804

ManufacturerRAZNO
Catalog numberGW95940
Type
EAN code8034035020056

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated voltage

230V

Power loss

32W

Number of protected poles

2

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.03A

Leakage current type

Other

Rated current

7.34A

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity according to EN 61009

6kA

Surge current capacity

3kA

Current limiting class

1

Ambient temperature during operating

-25 - 40°C

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Release characteristic

C

Concurrently switching neutral conductor

No

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Voltage type

AC

Pollution degree

2

Frequency

50/60 Hz

With interlocking device

No

Over voltage category

3

Width in number of modular spacings

2

Anti-nuisance tripping version

Yes

Flush-mounted installation

No

Built-in depth

72mm

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 - 35mm²

Connectable conductor cross section solid-core

35 - 35mm²

Disconnection characteristic

Short-time delayed


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW95940

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

2

Rated voltage

230V

Power loss

32W

Number of protected poles

2

Rated impulse withstand voltage Uimp

4kV

Rated fault current

0.03A

Leakage current type

Other

Rated current

7.34A

Rated insulation voltage Ui

500V

Rated short-circuit breaking capacity according to EN 61009

6kA

Surge current capacity

3kA

Current limiting class

1

Ambient temperature during operating

-25 .. 40°C

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Release characteristic

C

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Voltage type

AC

Pollution degree

2

Frequency

50/60 Hz

With interlocking device

Over voltage category

3

Width in number of modular spacings

2

Anti-nuisance tripping version

Flush-mounted installation

Built-in depth

72mm

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²

Disconnection characteristic

Short-time delayed