Technical specifications

Rated voltage

230V

Rated insulation voltage Ui

500V

Number of poles (total)

2

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated current

4.12A

Power loss

10W

Concurrently switching neutral conductor

No

Rated short-circuit breaking capacity according to EN 61009

6kA

Ambient temperature during operating

-25 - 40°C

Current limiting class

1

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Disconnection characteristic

Short-time delayed

Surge current capacity

3kA

Leakage current type

Other

Rated impulse withstand voltage Uimp

4kV

Frequency

50/60 Hz

Voltage type

AC

Rated fault current

0.03A

With interlocking device

No

Flush-mounted installation

No

Width in number of modular spacings

2

Built-in depth

72mm

Over voltage category

3

Anti-nuisance tripping version

Yes

Pollution degree

2

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 - 35mm²

Release characteristic

C

Connectable conductor cross section multi-wired

35 - 35mm²


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW95936

Main Product Image

Details

  • Circuit breakers and fuses
  • Earth leakage circuit breaker
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

230V

Rated insulation voltage Ui

500V

Number of poles (total)

2

Number of protected poles

2

Rated short-circuit breaking capacity Icn according to EN 61009-1

6kA

Rated current

4.12A

Power loss

10W

Concurrently switching neutral conductor

Rated short-circuit breaking capacity according to EN 61009

6kA

Ambient temperature during operating

-25 .. 40°C

Current limiting class

1

Rated short-circuit breaking capacity according to IEC 60947-2

6kA

Disconnection characteristic

Short-time delayed

Surge current capacity

3kA

Leakage current type

Other

Rated impulse withstand voltage Uimp

4kV

Frequency

50/60 Hz

Voltage type

AC

Rated fault current

0.03A

With interlocking device

Flush-mounted installation

Width in number of modular spacings

2

Built-in depth

72mm

Over voltage category

3

Anti-nuisance tripping version

Pollution degree

2

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

Release characteristic

C

Connectable conductor cross section multi-wired

35 .. 35mm²