Aleta.hr
Main Product Image

GW93246

Code: 1965798

ManufacturerRAZNO
Catalog numberGW93246
Type
EAN code8011564669079

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Voltage type

AC

Rated insulation voltage Ui

500V

Rated current

63A

Power loss

22.4W

Number of poles (total)

4

Release characteristic

C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Pollution degree

2

Concurrently switching neutral conductor

No

Number of protected poles

4

Frequency

50 - 60Hz

Additional equipment possible

Yes

Over voltage category

4

Flush-mounted installation

No

Rated voltage

400V

Width in number of modular spacings

6

Explosion-proof

No

Connectable conductor cross section multi-wired

50 - 50mm²

Ambient temperature during operating

-25 - 60°C

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

70 - 70mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW93246

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Voltage type

AC

Rated insulation voltage Ui

500V

Rated current

63A

Power loss

22.4W

Number of poles (total)

4

Release characteristic

C

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Pollution degree

2

Concurrently switching neutral conductor

Number of protected poles

4

Frequency

50 .. 60Hz

Additional equipment possible

Over voltage category

4

Flush-mounted installation

Rated voltage

400V

Width in number of modular spacings

6

Explosion-proof

Connectable conductor cross section multi-wired

50 .. 50mm²

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

70 .. 70mm²

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.