Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristic

C

Number of poles (total)

3

Number of protected poles

3

Rated voltage

400V

Built-in depth

72mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Rated current

40A

Rated insulation voltage Ui

500V

Frequency

50 - 60Hz

Flush-mounted installation

No

Power loss

10.5W

Concurrently switching neutral conductor

No

Additional equipment possible

Yes

Connectable conductor cross section solid-core

70 - 70mm²

Pollution degree

2

Explosion-proof

No

Over voltage category

4

Width in number of modular spacings

4.5

Ambient temperature during operating

-25 - 60°C

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

50 - 50mm²


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW93234

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristic

C

Number of poles (total)

3

Number of protected poles

3

Rated voltage

400V

Built-in depth

72mm

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Rated impulse withstand voltage Uimp

6kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

30kA

Rated current

40A

Rated insulation voltage Ui

500V

Frequency

50 .. 60Hz

Flush-mounted installation

Power loss

10.5W

Concurrently switching neutral conductor

Additional equipment possible

Connectable conductor cross section solid-core

70 .. 70mm²

Pollution degree

2

Explosion-proof

Over voltage category

4

Width in number of modular spacings

4.5

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Connectable conductor cross section multi-wired

50 .. 50mm²