Aleta.hr
Main Product Image

GW93309

Code: 1965749

ManufacturerRAZNO
Catalog numberGW93309
Type
EAN code8011564669109

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

400V

Voltage type

AC

Rated impulse withstand voltage Uimp

6kV

Frequency

50 - 60Hz

Built-in depth

72mm

Pollution degree

2

Rated current

125A

Concurrently switching neutral conductor

No

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

1

Rated insulation voltage Ui

500V

Additional equipment possible

Yes

Connectable conductor cross section multi-wired

50 - 50mm²

Connectable conductor cross section solid-core

70 - 70mm²

Degree of protection (IP)

IP20

Explosion-proof

No

Number of poles (total)

1

Ambient temperature during operating

-25 - 60°C

Power loss

11W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

16kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

4.5kA

Release characteristic

C

Over voltage category

4

Width in number of modular spacings

1.5

Flush-mounted installation

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW93309

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Rated voltage

400V

Voltage type

AC

Rated impulse withstand voltage Uimp

6kV

Frequency

50 .. 60Hz

Built-in depth

72mm

Pollution degree

2

Rated current

125A

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

1

Rated insulation voltage Ui

500V

Additional equipment possible

Connectable conductor cross section multi-wired

50 .. 50mm²

Connectable conductor cross section solid-core

70 .. 70mm²

Degree of protection (IP)

IP20

Explosion-proof

Number of poles (total)

1

Ambient temperature during operating

-25 .. 60°C

Power loss

11W

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

16kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

4.5kA

Release characteristic

C

Over voltage category

4

Width in number of modular spacings

1.5

Flush-mounted installation

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.