  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Rated current

10A

Release characteristic

C

Rated impulse withstand voltage Uimp

4kV

Frequency

50 - 60Hz

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Width in number of modular spacings

4

Flush-mounted installation

No

Degree of protection (IP)

IP20

Additional equipment possible

Yes

Pollution degree

2

Number of protected poles

4

Explosion-proof

No

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Voltage type

AC

Connectable conductor cross section solid-core

35 - 35mm²

Rated insulation voltage Ui

500V

Power loss

7.92W

Ambient temperature during operating

-25 - 60°C

Connectable conductor cross section multi-wired

35 - 35mm²

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Concurrently switching neutral conductor

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW92886

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Rated current

10A

Release characteristic

C

Rated impulse withstand voltage Uimp

4kV

Frequency

50 .. 60Hz

Number of poles (total)

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

25kA

Width in number of modular spacings

4

Flush-mounted installation

Degree of protection (IP)

IP20

Additional equipment possible

Pollution degree

2

Number of protected poles

4

Explosion-proof

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

25kA

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

40kA

Voltage type

AC

Connectable conductor cross section solid-core

35 .. 35mm²

Rated insulation voltage Ui

500V

Power loss

7.92W

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

35 .. 35mm²

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

25kA

Concurrently switching neutral conductor

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.