Technical specifications

Number of protected poles

3

Built-in depth

72mm

Number of poles (total)

3

Release characteristic

C

Rated current

63A

Rated voltage

400V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

20kA

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

12.5kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Power loss

14.76W

Flush-mounted installation

No

Over voltage category

3

Pollution degree

2

Explosion-proof

No

Connectable conductor cross section solid-core

35 - 35mm²

Concurrently switching neutral conductor

No

Degree of protection (IP)

IP20

Additional equipment possible

Yes

Width in number of modular spacings

3

Ambient temperature during operating

-25 - 60°C

Connectable conductor cross section multi-wired

35 - 35mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW92873

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Number of protected poles

3

Built-in depth

72mm

Number of poles (total)

3

Release characteristic

C

Rated current

63A

Rated voltage

400V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

20kA

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

12.5kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Power loss

14.76W

Flush-mounted installation

Over voltage category

3

Pollution degree

2

Explosion-proof

Connectable conductor cross section solid-core

35 .. 35mm²

Concurrently switching neutral conductor

Degree of protection (IP)

IP20

Additional equipment possible

Width in number of modular spacings

3

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

35 .. 35mm²

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.