Aleta.hr
Main Product Image

GW92553

Code: 1965689

ManufacturerRAZNO
Catalog numberGW92553
Type
EAN code8034035425554

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Number of protected poles

2

Release characteristic

B

Built-in depth

72mm

Rated insulation voltage Ui

500V

Rated current

50A

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Voltage type

AC

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Current limiting class

3

Concurrently switching neutral conductor

No

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Flush-mounted installation

No

Power loss

9.56W

Rated voltage

400V

Additional equipment possible

Yes

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 - 35mm²

Over voltage category

3

Ambient temperature during operating

-25 - 60°C

Pollution degree

3

Connectable conductor cross section multi-wired

35 - 35mm²

Width in number of modular spacings

2

Explosion-proof

No


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW92553

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Number of protected poles

2

Release characteristic

B

Built-in depth

72mm

Rated insulation voltage Ui

500V

Rated current

50A

Number of poles (total)

2

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Voltage type

AC

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Current limiting class

3

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Flush-mounted installation

Power loss

9.56W

Rated voltage

400V

Additional equipment possible

Degree of protection (IP)

IP20

Connectable conductor cross section solid-core

35 .. 35mm²

Over voltage category

3

Ambient temperature during operating

-25 .. 60°C

Pollution degree

3

Connectable conductor cross section multi-wired

35 .. 35mm²

Width in number of modular spacings

2

Explosion-proof