Aleta.hr
Main Product Image

GW92551

Code: 1965687

ManufacturerRAZNO
Catalog numberGW92551
Type
EAN code8034035425530

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Release characteristic

B

Rated current

32A

Number of poles (total)

2

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

AC

Number of protected poles

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Frequency

50 - 60Hz

Power loss

6.04W

Flush-mounted installation

No

Current limiting class

3

Concurrently switching neutral conductor

No

Width in number of modular spacings

2

Over voltage category

3

Additional equipment possible

Yes

Ambient temperature during operating

-25 - 60°C

Connectable conductor cross section multi-wired

35 - 35mm²

Pollution degree

3

Degree of protection (IP)

IP20

Explosion-proof

No

Connectable conductor cross section solid-core

35 - 35mm²


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW92551

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Release characteristic

B

Rated current

32A

Number of poles (total)

2

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Voltage type

AC

Number of protected poles

2

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated voltage

400V

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Frequency

50 .. 60Hz

Power loss

6.04W

Flush-mounted installation

Current limiting class

3

Concurrently switching neutral conductor

Width in number of modular spacings

2

Over voltage category

3

Additional equipment possible

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

35 .. 35mm²

Pollution degree

3

Degree of protection (IP)

IP20

Explosion-proof

Connectable conductor cross section solid-core

35 .. 35mm²

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.