Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Rated insulation voltage Ui

500V

Release characteristic

D

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated voltage

400V

Rated current

32A

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation

No

Current limiting class

3

Voltage type

AC

Concurrently switching neutral conductor

No

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Pollution degree

3

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

12.5kA

Frequency

50 - 60Hz

Power loss

9.36W

Degree of protection (IP)

IP20

Additional equipment possible

Yes

Width in number of modular spacings

4

Ambient temperature during operating

-25 - 60°C

Connectable conductor cross section solid-core

35 - 35mm²

Connectable conductor cross section multi-wired

35 - 35mm²

Explosion-proof

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW92790

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Rated insulation voltage Ui

500V

Release characteristic

D

Number of protected poles

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Rated voltage

400V

Rated current

32A

Number of poles (total)

4

Rated impulse withstand voltage Uimp

4kV

Flush-mounted installation

Current limiting class

3

Voltage type

AC

Concurrently switching neutral conductor

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Pollution degree

3

Over voltage category

3

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

12.5kA

Frequency

50 .. 60Hz

Power loss

9.36W

Degree of protection (IP)

IP20

Additional equipment possible

Width in number of modular spacings

4

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section solid-core

35 .. 35mm²

Connectable conductor cross section multi-wired

35 .. 35mm²

Explosion-proof