  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristic

D

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

4

Rated current

25A

Built-in depth

72mm

Rated voltage

400V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Current limiting class

3

Power loss

6.48W

Frequency

50 - 60Hz

Flush-mounted installation

No

Connectable conductor cross section multi-wired

35 - 35mm²

Additional equipment possible

Yes

Connectable conductor cross section solid-core

35 - 35mm²

Ambient temperature during operating

-25 - 60°C

Pollution degree

3

Width in number of modular spacings

4

Explosion-proof

No

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

No

Over voltage category

3


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW92789

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Release characteristic

D

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

10kA

Number of protected poles

4

Rated current

25A

Built-in depth

72mm

Rated voltage

400V

Rated insulation voltage Ui

500V

Rated impulse withstand voltage Uimp

4kV

Voltage type

AC

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

25kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

10kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

15kA

Current limiting class

3

Power loss

6.48W

Frequency

50 .. 60Hz

Flush-mounted installation

Connectable conductor cross section multi-wired

35 .. 35mm²

Additional equipment possible

Connectable conductor cross section solid-core

35 .. 35mm²

Ambient temperature during operating

-25 .. 60°C

Pollution degree

3

Width in number of modular spacings

4

Explosion-proof

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Over voltage category

3