Aleta.hr
Main Product Image

GW92491

Code: 1965581

ManufacturerRAZNO
Catalog numberGW92491
Type
EAN code8034035425318

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

4

Built-in depth

72mm

Rated voltage

400V

Voltage type

AC

Rated current

40A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Release characteristic

D

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated insulation voltage Ui

500V

Frequency

50 - 60Hz

Power loss

12.48W

Current limiting class

3

Flush-mounted installation

No

Concurrently switching neutral conductor

No

Over voltage category

3

Additional equipment possible

Yes

Pollution degree

3

Width in number of modular spacings

4

Ambient temperature during operating

-25 - 60°C

Connectable conductor cross section multi-wired

35 - 35mm²

Connectable conductor cross section solid-core

35 - 35mm²

Explosion-proof

No

Degree of protection (IP)

IP20


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW92491

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Number of poles (total)

4

Built-in depth

72mm

Rated voltage

400V

Voltage type

AC

Rated current

40A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Release characteristic

D

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated impulse withstand voltage Uimp

4kV

Number of protected poles

4

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Rated insulation voltage Ui

500V

Frequency

50 .. 60Hz

Power loss

12.48W

Current limiting class

3

Flush-mounted installation

Concurrently switching neutral conductor

Over voltage category

3

Additional equipment possible

Pollution degree

3

Width in number of modular spacings

4

Ambient temperature during operating

-25 .. 60°C

Connectable conductor cross section multi-wired

35 .. 35mm²

Connectable conductor cross section solid-core

35 .. 35mm²

Explosion-proof

Degree of protection (IP)

IP20

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.