Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Number of poles (total)

4

Voltage type

AC

Rated current

6A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated insulation voltage Ui

500V

Flush-mounted installation

No

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Current limiting class

3

Rated voltage

400V

Pollution degree

3

Over voltage category

3

Power loss

6.24W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Ambient temperature during operating

-25 - 60°C

Concurrently switching neutral conductor

No

Number of protected poles

4

Release characteristic

B

Frequency

50 - 60Hz

Connectable conductor cross section multi-wired

35 - 35mm²

Additional equipment possible

Yes

Rated impulse withstand voltage Uimp

4kV

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Connectable conductor cross section solid-core

35 - 35mm²

Explosion-proof

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW92285

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Number of poles (total)

4

Voltage type

AC

Rated current

6A

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated insulation voltage Ui

500V

Flush-mounted installation

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Current limiting class

3

Rated voltage

400V

Pollution degree

3

Over voltage category

3

Power loss

6.24W

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Ambient temperature during operating

-25 .. 60°C

Concurrently switching neutral conductor

Number of protected poles

4

Release characteristic

B

Frequency

50 .. 60Hz

Connectable conductor cross section multi-wired

35 .. 35mm²

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Degree of protection (IP)

IP20

Width in number of modular spacings

4

Connectable conductor cross section solid-core

35 .. 35mm²

Explosion-proof

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.