Technical specifications

Built-in depth

72mm

Release characteristic

B

Number of poles (total)

2

Rated current

13A

Rated voltage

400V

Rated insulation voltage Ui

500V

Frequency

50 - 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Flush-mounted installation

No

Concurrently switching neutral conductor

No

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Power loss

3.94W

Voltage type

AC

Rated impulse withstand voltage Uimp

4kV

Over voltage category

3

Connectable conductor cross section multi-wired

35 - 35mm²

Additional equipment possible

Yes

Number of protected poles

2

Ambient temperature during operating

-25 - 60°C

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Explosion-proof

No

Connectable conductor cross section solid-core

35 - 35mm²

Pollution degree

3


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW92254

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Release characteristic

B

Number of poles (total)

2

Rated current

13A

Rated voltage

400V

Rated insulation voltage Ui

500V

Frequency

50 .. 60Hz

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

10kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Flush-mounted installation

Concurrently switching neutral conductor

Current limiting class

3

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

20kA

Power loss

3.94W

Voltage type

AC

Rated impulse withstand voltage Uimp

4kV

Over voltage category

3

Connectable conductor cross section multi-wired

35 .. 35mm²

Additional equipment possible

Number of protected poles

2

Ambient temperature during operating

-25 .. 60°C

Degree of protection (IP)

IP20

Width in number of modular spacings

2

Explosion-proof

Connectable conductor cross section solid-core

35 .. 35mm²

Pollution degree

3