Aleta.hr

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Release characteristic

C

Rated current

20A

Rated insulation voltage Ui

500V

Voltage type

AC

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Over voltage category

3

Current limiting class

1

Power loss

9.08W

Flush-mounted installation

No

Frequency

50 - 60Hz

Number of protected poles

4

Additional equipment possible

Yes

Rated impulse withstand voltage Uimp

4kV

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

No

Ambient temperature during operating

-25 - 60°C

Rated voltage

400V

Pollution degree

3

Connectable conductor cross section multi-wired

10 - 10mm²

Connectable conductor cross section solid-core

16 - 16mm²

Explosion-proof

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

GW90288

Main Product Image

Details

  • Circuit breakers and fuses
  • Miniature circuit breaker (MCB)
  • 1 KOM
  • GEWISS

Technical specifications

Built-in depth

72mm

Release characteristic

C

Rated current

20A

Rated insulation voltage Ui

500V

Voltage type

AC

Number of poles (total)

4

Rated short-circuit breaking capacity Icn according to EN 60898 at 230 V

6kA

Rated short-circuit breaking capacity Icn according to EN 60898 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 400 V

6kA

Rated short-circuit breaking capacity Icu according to IEC 60947-2 at 230 V

10kA

Over voltage category

3

Current limiting class

1

Power loss

9.08W

Flush-mounted installation

Frequency

50 .. 60Hz

Number of protected poles

4

Additional equipment possible

Rated impulse withstand voltage Uimp

4kV

Width in number of modular spacings

2

Degree of protection (IP)

IP20

Concurrently switching neutral conductor

Ambient temperature during operating

-25 .. 60°C

Rated voltage

400V

Pollution degree

3

Connectable conductor cross section multi-wired

10 .. 10mm²

Connectable conductor cross section solid-core

16 .. 16mm²

Explosion-proof

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.