Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as emergency stop installation
No
Version as main switch
No
Version as maintenance-/service switch
Yes
Version as reversing switch
No
Number of switches
1
Max. rated operation voltage Ue AC
0V
Rated operating voltage
600 - 1000V
Version as safety switch
No
Number of auxiliary contacts as normally closed contact
0
Conditioned rated short-circuit current Iq
0kA
Rated permanent current Iu
0A
Number of auxiliary contacts as normally open contact
0
Switching power at 400 V
0kW
Number of poles
2
Number of auxiliary contacts as change-over contact
0
Rated operation power at AC-23, 400 V
0kW
Rated permanent current at AC-23, 400 V
0A
Rated operation power at AC-3, 400 V
0kW
Suitable for distribution board installation
Yes
Rated short-time withstand current lcw
1200kA
Rated permanent current at AC-21, 400 V
0A
Suitable for intermediate mounting
No
Suitable for front mounting centre
No
Device construction
Built-in device fixed built-in technique
Motor drive integrated
No
Suitable for front mounting 4-hole
No
Interlockable
No
Motor drive optional
No
Type of control element
Rocker lever
Colour control element
Grey
With pre-assembled cabling
No
Type of electrical connection of main circuit
Frame clamp
Voltage release optional
Yes
Suitable for floor mounting
No
Degree of protection (IP), front side
IP20
Height
77mm
Degree of protection (NEMA)
Other
Depth
113mm
Width
54mm
From same serie
PV-DIS-06-100/2

Details
- Low-voltage industrial components
- Switch disconnector (low voltage)
- 1 KOM
- EATON
Technical specifications
Version as emergency stop installation
Version as main switch
Version as maintenance-/service switch
Version as reversing switch
Number of switches
1
Max. rated operation voltage Ue AC
0V
Rated operating voltage
600 .. 1000V
Version as safety switch
Number of auxiliary contacts as normally closed contact
0
Conditioned rated short-circuit current Iq
0kA
Rated permanent current Iu
0A
Number of auxiliary contacts as normally open contact
0
Switching power at 400 V
0kW
Number of poles
2
Number of auxiliary contacts as change-over contact
0
Rated operation power at AC-23, 400 V
0kW
Rated permanent current at AC-23, 400 V
0A
Rated operation power at AC-3, 400 V
0kW
Suitable for distribution board installation
Rated short-time withstand current lcw
1200kA
Rated permanent current at AC-21, 400 V
0A
Suitable for intermediate mounting
Suitable for front mounting centre
Device construction
Built-in device fixed built-in technique
Motor drive integrated
Suitable for front mounting 4-hole
Interlockable
Motor drive optional
Type of control element
Rocker lever
Colour control element
Grey
With pre-assembled cabling
Type of electrical connection of main circuit
Frame clamp
Voltage release optional
Suitable for floor mounting
Degree of protection (IP), front side
IP20
Height
77mm
Degree of protection (NEMA)
Other
Depth
113mm
Width
54mm
From same serie