Technical specifications
Power loss
4.71W
Rated voltage
690 - 690V
Suitable for DIN rail (top hat rail) mounting
No
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Spring clamp connection
Overload release current setting
2.5 - 2.5A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
With integrated under voltage release
No
Rated permanent current Iu
2.5A
Adjustment range short-term delayed short-circuit release
0 - 0A
Position of connection for main current circuit
Other
With switched-off indicator
No
Type of control element
Turn button
Adjustment range undelayed short-circuit release
50 - 50A
Number of auxiliary contacts as normally open contact
0
Device construction
Built-in device fixed built-in technique
Number of poles
3
DIN rail (top hat rail) mounting optional
Yes
Integrated earth fault protection
No
Complete device with protection unit
No
Motor drive integrated
No
Degree of protection (IP)
IP20
Motor drive optional
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
Related products
From same serie
PKZM0-2,5-T-PI

Details
- Low-voltage industrial components
- Power circuit-breaker for trafo/generator/installation protection
- 1 KOM
- EATON
Technical specifications
Power loss
4.71W
Rated voltage
690 .. 690V
Suitable for DIN rail (top hat rail) mounting
Number of auxiliary contacts as change-over contact
0
Number of auxiliary contacts as normally closed contact
0
Type of electrical connection of main circuit
Spring clamp connection
Overload release current setting
2.5 .. 2.5A
Rated short-circuit breaking capacity lcu at 400 V, 50 Hz
150kA
With integrated under voltage release
Rated permanent current Iu
2.5A
Adjustment range short-term delayed short-circuit release
0 .. 0A
Position of connection for main current circuit
Other
With switched-off indicator
Type of control element
Turn button
Adjustment range undelayed short-circuit release
50 .. 50A
Number of auxiliary contacts as normally open contact
0
Device construction
Built-in device fixed built-in technique
Number of poles
3
DIN rail (top hat rail) mounting optional
Integrated earth fault protection
Complete device with protection unit
Motor drive integrated
Degree of protection (IP)
IP20
Motor drive optional