Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation current Ie
16.7A
Rated operation power at AC-3, 400 V
7.5kW
Rated operation current at AC-3, 400 V
17A
Rated control supply voltage Us at DC
24 - 24V
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated power, 575 V, 60 Hz, 3-phase
0kW
Number of auxiliary contacts as normally open contact
1
Ambient temperature, upper operating limit
55°C
With short-circuit release
Yes
Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as normally closed contact
0
Rated operation power at AC-3, 230 V, 3-phase
4kW
Temperature compensated overload protection
Yes
Rail mounting possible
No
Rated conditional short-circuit current, type 2, 400 V
100000A
External reset possible
No
Number of indicator lights
0
Voltage type for actuating
DC
Number of command positions
0
Supporting protocol for DeviceNet
No
Supporting protocol for ASI
No
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Overload release current setting
8 - 32A
Supporting protocol for INTERBUS
No
Rated control supply voltage Us at AC 50HZ
0 - 0V
Supporting protocol for PROFINET CBA
No
Supporting protocol for Modbus
No
With fuse
No
Supporting protocol for Data-Highway
No
Supporting protocol for CAN
No
Supporting protocol for SUCONET
No
Supporting protocol for PROFIBUS
No
With transformer
No
Degree of protection (IP)
IP20
Supporting protocol for SERCOS
No
Supporting protocol for PROFINET IO
No
Rated conditional short-circuit current, type 2, 230 V
100000A
Suitable for emergency stop
No
Supporting protocol for TCP/IP
No
Coordination class according to IEC 60947-4-3
Class 2
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Degree of protection (NEMA)
Other
Release class
Adjustable
Supporting protocol for LON
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Supporting protocol for SafetyBUS p
No
Width
45mm
Height
206mm
Depth
149.5mm
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
From same serie
MSC-DME-32-M17(24VDC)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated operation current Ie
16.7A
Rated operation power at AC-3, 400 V
7.5kW
Rated operation current at AC-3, 400 V
17A
Rated control supply voltage Us at DC
24 .. 24V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated power, 575 V, 60 Hz, 3-phase
0kW
Number of auxiliary contacts as normally open contact
1
Ambient temperature, upper operating limit
55°C
With short-circuit release
Type of electrical connection of main circuit
Screw connection
Number of auxiliary contacts as normally closed contact
0
Rated operation power at AC-3, 230 V, 3-phase
4kW
Temperature compensated overload protection
Rail mounting possible
Rated conditional short-circuit current, type 2, 400 V
100000A
External reset possible
Number of indicator lights
0
Voltage type for actuating
DC
Number of command positions
0
Supporting protocol for DeviceNet
Supporting protocol for ASI
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Overload release current setting
8 .. 32A
Supporting protocol for INTERBUS
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Supporting protocol for PROFINET CBA
Supporting protocol for Modbus
With fuse
Supporting protocol for Data-Highway
Supporting protocol for CAN
Supporting protocol for SUCONET
Supporting protocol for PROFIBUS
With transformer
Degree of protection (IP)
IP20
Supporting protocol for SERCOS
Supporting protocol for PROFINET IO
Rated conditional short-circuit current, type 2, 230 V
100000A
Suitable for emergency stop
Supporting protocol for TCP/IP
Coordination class according to IEC 60947-4-3
Class 2
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Degree of protection (NEMA)
Other
Release class
Adjustable
Supporting protocol for LON
Supporting protocol for Foundation Fieldbus
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Supporting protocol for SafetyBUS p
Width
45mm
Height
206mm
Depth
149.5mm
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
From same serie
We use cookies to enhance your experience.