Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
With short-circuit release
Yes
Rated control supply voltage Us at AC 50HZ
0 - 0V
Rated control supply voltage Us at AC 60HZ
0 - 0V
Voltage type for actuating
DC
Rated control supply voltage Us at DC
24 - 24V
Rated operation power at AC-3, 400 V
5.5kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 230 V, 3-phase
3kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Overload release current setting
8 - 12A
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Number of auxiliary contacts as normally closed contact
0
Rated operation current Ie
11.3A
Number of auxiliary contacts as normally open contact
1
Rated operation current at AC-3, 400 V
12A
Temperature compensated overload protection
Yes
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Coordination class according to IEC 60947-4-3
Class 2
Release class
CLASS 10 A
Degree of protection (IP)
IP20
With fuse
No
External reset possible
No
Rail mounting possible
No
Suitable for emergency stop
No
With transformer
No
Degree of protection (NEMA)
Other
Supporting protocol for TCP/IP
No
Number of indicator lights
0
Supporting protocol for PROFIBUS
No
Ambient temperature, upper operating limit
55°C
Supporting protocol for Data-Highway
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for LON
No
Supporting protocol for ASI
No
Supporting protocol for PROFINET IO
No
Rated conditional short-circuit current, type 2, 400 V
50000A
Supporting protocol for SERCOS
No
Supporting protocol for DeviceNet
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for INTERBUS
No
Power consumption
0.9W
Number of command positions
0
Supporting protocol for Modbus
No
Supporting protocol for SUCONET
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for CAN
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Height
197mm
Depth
97.5mm
Width
45mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
MSC-DM-12-M17(24VDC)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
With short-circuit release
Rated control supply voltage Us at AC 50HZ
0 .. 0V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Voltage type for actuating
DC
Rated control supply voltage Us at DC
24 .. 24V
Rated operation power at AC-3, 400 V
5.5kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated operation power at AC-3, 230 V, 3-phase
3kW
Rated power, 460 V, 60 Hz, 3-phase
0kW
Overload release current setting
8 .. 12A
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Number of auxiliary contacts as normally closed contact
0
Rated operation current Ie
11.3A
Number of auxiliary contacts as normally open contact
1
Rated operation current at AC-3, 400 V
12A
Temperature compensated overload protection
Type of electrical connection of main circuit
Screw connection
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Coordination class according to IEC 60947-4-3
Class 2
Release class
CLASS 10 A
Degree of protection (IP)
IP20
With fuse
External reset possible
Rail mounting possible
Suitable for emergency stop
With transformer
Degree of protection (NEMA)
Other
Supporting protocol for TCP/IP
Number of indicator lights
0
Supporting protocol for PROFIBUS
Ambient temperature, upper operating limit
55°C
Supporting protocol for Data-Highway
Supporting protocol for PROFINET CBA
Supporting protocol for LON
Supporting protocol for ASI
Supporting protocol for PROFINET IO
Rated conditional short-circuit current, type 2, 400 V
50000A
Supporting protocol for SERCOS
Supporting protocol for DeviceNet
Supporting protocol for Foundation Fieldbus
Supporting protocol for INTERBUS
Power consumption
0.9W
Number of command positions
0
Supporting protocol for Modbus
Supporting protocol for SUCONET
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for EtherNet/IP
Supporting protocol for CAN
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for SafetyBUS p
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Height
197mm
Depth
97.5mm
Width
45mm
From same serie