Technical specifications
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 50HZ
230 - 230V
With short-circuit release
Yes
Rated operation power at AC-3, 230 V, 3-phase
3kW
Power consumption
1.4W
Release class
CLASS 10 A
Overload release current setting
8 - 12A
Temperature compensated overload protection
Yes
Rated operation power at AC-3, 400 V
5.5kW
Type of electrical connection of main circuit
Screw connection
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rail mounting possible
No
Rated control supply voltage Us at DC
0 - 0V
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
12A
Number of auxiliary contacts as normally open contact
1
Rated operation current Ie
11.3A
Number of command positions
0
Suitable for emergency stop
No
Ambient temperature, upper operating limit
55°C
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Voltage type for actuating
AC
Number of indicator lights
0
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Number of auxiliary contacts as normally closed contact
0
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 400 V
0A
Coordination class according to IEC 60947-4-3
Class 1
With transformer
No
Rated conditional short-circuit current, type 2, 230 V
0A
External reset possible
No
Supporting protocol for PROFIBUS
No
With fuse
No
Supporting protocol for Modbus
No
Degree of protection (IP)
IP20
Supporting protocol for LON
No
Supporting protocol for SUCONET
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for INTERBUS
No
Supporting protocol for CAN
No
Degree of protection (NEMA)
Other
Supporting protocol for Data-Highway
No
Supporting protocol for DeviceNet
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for ASI
No
Supporting protocol for PROFINET IO
No
Supporting protocol for TCP/IP
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for other bus systems
No
Supporting protocol for SafetyBUS p
No
Height
170mm
Width
45mm
Depth
76mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
MSC-DM-12-M12(230V50HZ)

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
Rated control supply voltage Us at AC 50HZ
230 .. 230V
With short-circuit release
Rated operation power at AC-3, 230 V, 3-phase
3kW
Power consumption
1.4W
Release class
CLASS 10 A
Overload release current setting
8 .. 12A
Temperature compensated overload protection
Rated operation power at AC-3, 400 V
5.5kW
Type of electrical connection of main circuit
Screw connection
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rail mounting possible
Rated control supply voltage Us at DC
0 .. 0V
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
12A
Number of auxiliary contacts as normally open contact
1
Rated operation current Ie
11.3A
Number of command positions
0
Suitable for emergency stop
Ambient temperature, upper operating limit
55°C
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Voltage type for actuating
AC
Number of indicator lights
0
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Number of auxiliary contacts as normally closed contact
0
Rated power, 575 V, 60 Hz, 3-phase
0kW
Rated conditional short-circuit current, type 2, 400 V
0A
Coordination class according to IEC 60947-4-3
Class 1
With transformer
Rated conditional short-circuit current, type 2, 230 V
0A
External reset possible
Supporting protocol for PROFIBUS
With fuse
Supporting protocol for Modbus
Degree of protection (IP)
IP20
Supporting protocol for LON
Supporting protocol for SUCONET
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for INTERBUS
Supporting protocol for CAN
Degree of protection (NEMA)
Other
Supporting protocol for Data-Highway
Supporting protocol for DeviceNet
Supporting protocol for Foundation Fieldbus
Supporting protocol for ASI
Supporting protocol for PROFINET IO
Supporting protocol for TCP/IP
Supporting protocol for PROFINET CBA
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for other bus systems
Supporting protocol for SafetyBUS p
Height
170mm
Width
45mm
Depth
76mm
From same serie
We use cookies to enhance your experience.