

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase
0.75kW
Rated control supply voltage Us at AC 50HZ
230 - 230V
Rated control supply voltage Us at AC 60HZ
0 - 0V
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Voltage type for actuating
AC
Rated control supply voltage Us at DC
0 - 0V
Rated operation current Ie
3.6A
Rated operation power at AC-3, 400 V
1.5kW
Overload release current setting
2.5 - 4A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
4A
With short-circuit release
Yes
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Power consumption
1.4W
Rated conditional short-circuit current, type 2, 400 V
50000A
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as normally closed contact
0
Temperature compensated overload protection
Yes
Ambient temperature, upper operating limit
55°C
Release class
CLASS 10
Type of electrical connection of main circuit
Screw connection
Coordination class according to IEC 60947-4-3
Class 2
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Number of indicator lights
0
External reset possible
No
Rail mounting possible
No
With transformer
No
Number of command positions
0
With fuse
No
Suitable for emergency stop
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for PROFIsafe
No
Supporting protocol for SafetyBUS p
No
Supporting protocol for other bus systems
No
Width
45mm
Height
200mm
Depth
154mm
Degree of protection (NEMA)
Other
Degree of protection (IP)
IP20
Supporting protocol for TCP/IP
No
Supporting protocol for PROFIBUS
No
Supporting protocol for CAN
No
Supporting protocol for INTERBUS
No
Supporting protocol for ASI
No
Supporting protocol for Modbus
No
Supporting protocol for Data-Highway
No
Supporting protocol for SUCONET
No
Supporting protocol for DeviceNet
No
Supporting protocol for LON
No
Supporting protocol for PROFINET CBA
No
Supporting protocol for SERCOS
No
Supporting protocol for EtherNet/IP
No
Supporting protocol for PROFINET IO
No
Supporting protocol for Foundation Fieldbus
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
MSC-D-4-M7(230V50HZ)/BBA

Details
- Low-voltage industrial components
- Motor starter/motor starter combination
- 1 KOM
- EATON
Technical specifications
Type of motor starter
Direct online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase
0.75kW
Rated control supply voltage Us at AC 50HZ
230 .. 230V
Rated control supply voltage Us at AC 60HZ
0 .. 0V
Rated power, 460 V, 60 Hz, 3-phase
0kW
Rated power, 575 V, 60 Hz, 3-phase
0kW
Voltage type for actuating
AC
Rated control supply voltage Us at DC
0 .. 0V
Rated operation current Ie
3.6A
Rated operation power at AC-3, 400 V
1.5kW
Overload release current setting
2.5 .. 4A
Rated conditional short-circuit current, type 1, 480 Y/277 V
0A
Rated operation current at AC-3, 400 V
4A
With short-circuit release
Rated conditional short-circuit current, type 2, 230 V
50000A
Rated conditional short-circuit current, type 1, 600 Y/347 V
0A
Power consumption
1.4W
Rated conditional short-circuit current, type 2, 400 V
50000A
Number of auxiliary contacts as normally open contact
1
Number of auxiliary contacts as normally closed contact
0
Temperature compensated overload protection
Ambient temperature, upper operating limit
55°C
Release class
CLASS 10
Type of electrical connection of main circuit
Screw connection
Coordination class according to IEC 60947-4-3
Class 2
Type of electrical connection for auxiliary- and control current circuit
Screw connection
Number of indicator lights
0
External reset possible
Rail mounting possible
With transformer
Number of command positions
0
With fuse
Suitable for emergency stop
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for DeviceNet Safety
Supporting protocol for INTERBUS-Safety
Supporting protocol for PROFIsafe
Supporting protocol for SafetyBUS p
Supporting protocol for other bus systems
Width
45mm
Height
200mm
Depth
154mm
Degree of protection (NEMA)
Other
Degree of protection (IP)
IP20
Supporting protocol for TCP/IP
Supporting protocol for PROFIBUS
Supporting protocol for CAN
Supporting protocol for INTERBUS
Supporting protocol for ASI
Supporting protocol for Modbus
Supporting protocol for Data-Highway
Supporting protocol for SUCONET
Supporting protocol for DeviceNet
Supporting protocol for LON
Supporting protocol for PROFINET CBA
Supporting protocol for SERCOS
Supporting protocol for EtherNet/IP
Supporting protocol for PROFINET IO
Supporting protocol for Foundation Fieldbus
From same serie
We use cookies to enhance your experience.