MSC-D-12-M17(230V50HZ)/BBA

Code: 1957867

ManufacturerRAZNO
Catalog number102960
Type
EAN code4015081027996

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

With short-circuit release

Yes

Rated control supply voltage Us at AC 50HZ

230 - 230V

Rated control supply voltage Us at AC 60HZ

0 - 0V

Rated operation power at AC-3, 230 V, 3-phase

3kW

Rated control supply voltage Us at DC

0 - 0V

Rated operation power at AC-3, 400 V

5.5kW

Voltage type for actuating

AC

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

12A

Rated operation current Ie

11.3A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Power consumption

2.1W

Number of auxiliary contacts as normally open contact

1

Rated conditional short-circuit current, type 2, 230 V

50000A

Ambient temperature, upper operating limit

55°C

Number of auxiliary contacts as normally closed contact

0

Release class

CLASS 10 A

Temperature compensated overload protection

Yes

Type of electrical connection of main circuit

Screw connection

Rail mounting possible

No

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With transformer

No

Overload release current setting

8 - 12A

Rated conditional short-circuit current, type 2, 400 V

50000A

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for other bus systems

No

Width

45mm

Height

200mm

Depth

156mm

Suitable for emergency stop

No

Number of command positions

0

Coordination class according to IEC 60947-4-3

Class 2

Number of indicator lights

0

With fuse

No

External reset possible

No

Degree of protection (IP)

IP00

Degree of protection (NEMA)

Other

Supporting protocol for TCP/IP

No

Supporting protocol for PROFIBUS

No

Supporting protocol for CAN

No

Supporting protocol for INTERBUS

No

Supporting protocol for Modbus

No

Supporting protocol for ASI

No

Supporting protocol for Data-Highway

No

Supporting protocol for PROFINET IO

No

Supporting protocol for SUCONET

No

Supporting protocol for DeviceNet

No

Supporting protocol for LON

No

Supporting protocol for SERCOS

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for PROFINET CBA

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-D-12-M17(230V50HZ)/BBA

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

With short-circuit release

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated operation power at AC-3, 230 V, 3-phase

3kW

Rated control supply voltage Us at DC

0 .. 0V

Rated operation power at AC-3, 400 V

5.5kW

Voltage type for actuating

AC

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

12A

Rated operation current Ie

11.3A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Power consumption

2.1W

Number of auxiliary contacts as normally open contact

1

Rated conditional short-circuit current, type 2, 230 V

50000A

Ambient temperature, upper operating limit

55°C

Number of auxiliary contacts as normally closed contact

0

Release class

CLASS 10 A

Temperature compensated overload protection

Type of electrical connection of main circuit

Screw connection

Rail mounting possible

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With transformer

Overload release current setting

8 .. 12A

Rated conditional short-circuit current, type 2, 400 V

50000A

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for SafetyBUS p

Supporting protocol for other bus systems

Width

45mm

Height

200mm

Depth

156mm

Suitable for emergency stop

Number of command positions

0

Coordination class according to IEC 60947-4-3

Class 2

Number of indicator lights

0

With fuse

External reset possible

Degree of protection (IP)

IP00

Degree of protection (NEMA)

Other

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for Modbus

Supporting protocol for ASI

Supporting protocol for Data-Highway

Supporting protocol for PROFINET IO

Supporting protocol for SUCONET

Supporting protocol for DeviceNet

Supporting protocol for LON

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET CBA