Aleta.hr
Main Product Image

MSC-D-12-M12(230V50HZ)/BBA

Code: 1957866

ManufacturerRAZNO
Catalog number102957
Type
EAN code4015081027965

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

With short-circuit release

Yes

Rated control supply voltage Us at DC

0 - 0V

Rated control supply voltage Us at AC 60HZ

0 - 0V

Rated operation power at AC-3, 230 V, 3-phase

3kW

Voltage type for actuating

AC

Rated control supply voltage Us at AC 50HZ

230 - 230V

Rated operation power at AC-3, 400 V

5.5kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

12A

Overload release current setting

8 - 12A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated operation current Ie

11.3A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 230 V

0A

Power consumption

1.4W

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

1

Number of auxiliary contacts as normally closed contact

0

Temperature compensated overload protection

Yes

Release class

CLASS 10 A

Rail mounting possible

No

Ambient temperature, upper operating limit

55°C

Number of command positions

0

Rated conditional short-circuit current, type 2, 400 V

100A

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Coordination class according to IEC 60947-4-3

Class 1

With transformer

No

Suitable for emergency stop

No

Number of indicator lights

0

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for SafetyBUS p

No

Supporting protocol for PROFIsafe

No

Supporting protocol for other bus systems

No

Width

45mm

Height

200mm

Depth

154mm

External reset possible

No

With fuse

No

Degree of protection (NEMA)

Other

Degree of protection (IP)

IP20

Supporting protocol for TCP/IP

No

Supporting protocol for PROFIBUS

No

Supporting protocol for CAN

No

Supporting protocol for INTERBUS

No

Supporting protocol for ASI

No

Supporting protocol for Modbus

No

Supporting protocol for DeviceNet

No

Supporting protocol for SUCONET

No

Supporting protocol for Data-Highway

No

Supporting protocol for LON

No

Supporting protocol for PROFINET CBA

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for PROFINET IO

No

Supporting protocol for SERCOS

No

Supporting protocol for EtherNet/IP

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-D-12-M12(230V50HZ)/BBA

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

With short-circuit release

Rated control supply voltage Us at DC

0 .. 0V

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated operation power at AC-3, 230 V, 3-phase

3kW

Voltage type for actuating

AC

Rated control supply voltage Us at AC 50HZ

230 .. 230V

Rated operation power at AC-3, 400 V

5.5kW

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

12A

Overload release current setting

8 .. 12A

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Rated operation current Ie

11.3A

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Rated conditional short-circuit current, type 2, 230 V

0A

Power consumption

1.4W

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

1

Number of auxiliary contacts as normally closed contact

0

Temperature compensated overload protection

Release class

CLASS 10 A

Rail mounting possible

Ambient temperature, upper operating limit

55°C

Number of command positions

0

Rated conditional short-circuit current, type 2, 400 V

100A

Type of electrical connection for auxiliary- and control current circuit

Screw connection

Coordination class according to IEC 60947-4-3

Class 1

With transformer

Suitable for emergency stop

Number of indicator lights

0

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for SafetyBUS p

Supporting protocol for PROFIsafe

Supporting protocol for other bus systems

Width

45mm

Height

200mm

Depth

154mm

External reset possible

With fuse

Degree of protection (NEMA)

Other

Degree of protection (IP)

IP20

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for Data-Highway

Supporting protocol for LON

Supporting protocol for PROFINET CBA

Supporting protocol for Foundation Fieldbus

Supporting protocol for PROFINET IO

Supporting protocol for SERCOS

Supporting protocol for EtherNet/IP

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.