Aleta.hr
Main Product Image

MSC-D-10-M7(230V50HZ)/BBA

Code: 1957864

ManufacturerRAZNO
Catalog number102955
Type
EAN code4015081027941

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Rated control supply voltage Us at AC 50HZ

230 - 230V

With short-circuit release

Yes

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Voltage type for actuating

AC

Rated operation power at AC-3, 400 V

3kW

Rated operation current Ie

6.6A

Rated control supply voltage Us at AC 60HZ

0 - 0V

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

7A

Rated conditional short-circuit current, type 2, 400 V

100A

Rated conditional short-circuit current, type 2, 230 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Ambient temperature, upper operating limit

55°C

Number of auxiliary contacts as normally closed contact

0

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With transformer

No

Release class

CLASS 10 A

Power consumption

1.4W

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

1

Temperature compensated overload protection

Yes

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rail mounting possible

No

Overload release current setting

6.3 - 10A

Rated control supply voltage Us at DC

0 - 0V

Number of command positions

0

With fuse

No

Coordination class according to IEC 60947-4-3

Class 1

Suitable for emergency stop

No

Degree of protection (IP)

IP20

Number of indicator lights

0

External reset possible

No

Supporting protocol for AS-Interface Safety at Work

No

Supporting protocol for DeviceNet Safety

No

Supporting protocol for INTERBUS-Safety

No

Supporting protocol for PROFIsafe

No

Supporting protocol for other bus systems

No

Supporting protocol for SafetyBUS p

No

Height

200mm

Depth

154mm

Width

45mm

Degree of protection (NEMA)

Other

Supporting protocol for TCP/IP

No

Supporting protocol for PROFIBUS

No

Supporting protocol for CAN

No

Supporting protocol for INTERBUS

No

Supporting protocol for ASI

No

Supporting protocol for Modbus

No

Supporting protocol for Data-Highway

No

Supporting protocol for DeviceNet

No

Supporting protocol for SUCONET

No

Supporting protocol for LON

No

Supporting protocol for PROFINET IO

No

Supporting protocol for SERCOS

No

Supporting protocol for Foundation Fieldbus

No

Supporting protocol for EtherNet/IP

No

Supporting protocol for PROFINET CBA

No


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

MSC-D-10-M7(230V50HZ)/BBA

Main Product Image

Details

  • Low-voltage industrial components
  • Motor starter/motor starter combination
  • 1 KOM
  • EATON

Technical specifications

Type of motor starter

Direct online starter (DOL)

Rated control supply voltage Us at AC 50HZ

230 .. 230V

With short-circuit release

Rated operation power at AC-3, 230 V, 3-phase

1.5kW

Voltage type for actuating

AC

Rated operation power at AC-3, 400 V

3kW

Rated operation current Ie

6.6A

Rated control supply voltage Us at AC 60HZ

0 .. 0V

Rated power, 460 V, 60 Hz, 3-phase

0kW

Rated operation current at AC-3, 400 V

7A

Rated conditional short-circuit current, type 2, 400 V

100A

Rated conditional short-circuit current, type 2, 230 V

0A

Rated conditional short-circuit current, type 1, 480 Y/277 V

0A

Ambient temperature, upper operating limit

55°C

Number of auxiliary contacts as normally closed contact

0

Rated conditional short-circuit current, type 1, 600 Y/347 V

0A

Type of electrical connection for auxiliary- and control current circuit

Screw connection

With transformer

Release class

CLASS 10 A

Power consumption

1.4W

Type of electrical connection of main circuit

Screw connection

Number of auxiliary contacts as normally open contact

1

Temperature compensated overload protection

Rated power, 575 V, 60 Hz, 3-phase

0kW

Rail mounting possible

Overload release current setting

6.3 .. 10A

Rated control supply voltage Us at DC

0 .. 0V

Number of command positions

0

With fuse

Coordination class according to IEC 60947-4-3

Class 1

Suitable for emergency stop

Degree of protection (IP)

IP20

Number of indicator lights

0

External reset possible

Supporting protocol for AS-Interface Safety at Work

Supporting protocol for DeviceNet Safety

Supporting protocol for INTERBUS-Safety

Supporting protocol for PROFIsafe

Supporting protocol for other bus systems

Supporting protocol for SafetyBUS p

Height

200mm

Depth

154mm

Width

45mm

Degree of protection (NEMA)

Other

Supporting protocol for TCP/IP

Supporting protocol for PROFIBUS

Supporting protocol for CAN

Supporting protocol for INTERBUS

Supporting protocol for ASI

Supporting protocol for Modbus

Supporting protocol for Data-Highway

Supporting protocol for DeviceNet

Supporting protocol for SUCONET

Supporting protocol for LON

Supporting protocol for PROFINET IO

Supporting protocol for SERCOS

Supporting protocol for Foundation Fieldbus

Supporting protocol for EtherNet/IP

Supporting protocol for PROFINET CBA

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

We use cookies to enhance your experience.