Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
Other
Alignment of the control element
Other
Length of sensor
16mm
Forced opening
Yes
With status indication
No
Type of control element
None
Diameter sensor
0mm
Switching function latching
No
Type of interface
None
Suitable for safety functions
No
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at AC-15, 230 V
1.5A
Rated operation current Ie at DC-13, 230 V
0.1A
Construction type housing
Cuboid
Number of contacts as normally open contact
1
Width sensor
30mm
Explosion safety category for gas
None
Rated operation current Ie at DC-13, 125 V
0A
Number of contacts as normally closed contact
1
Switching function
Quick-break switch
Height of sensor
52mm
Explosion safety category for dust
None
Output electronic
No
Material housing
Metal
Ambient temperature during operating
-25 - 70°C
Number of contacts as change-over contact
0
Number of safety auxiliary contacts
0
Degree of protection (IP)
IP66
Type of electric connection
Plug-in connection others
Coating housing
Other
Rated operation current Ie at AC-15, 125 V
0A
Type of interface for safety communication
None
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
ZCMD61

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Housing according to norm
Other
Alignment of the control element
Other
Length of sensor
16mm
Forced opening
With status indication
Type of control element
None
Diameter sensor
0mm
Switching function latching
Type of interface
None
Suitable for safety functions
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Rated operation current Ie at AC-15, 230 V
1.5A
Rated operation current Ie at DC-13, 230 V
0.1A
Construction type housing
Cuboid
Number of contacts as normally open contact
1
Width sensor
30mm
Explosion safety category for gas
None
Rated operation current Ie at DC-13, 125 V
0A
Number of contacts as normally closed contact
1
Switching function
Quick-break switch
Height of sensor
52mm
Explosion safety category for dust
None
Output electronic
Material housing
Metal
Ambient temperature during operating
-25 .. 70°C
Number of contacts as change-over contact
0
Number of safety auxiliary contacts
0
Degree of protection (IP)
IP66
Type of electric connection
Plug-in connection others
Coating housing
Other
Rated operation current Ie at AC-15, 125 V
0A
Type of interface for safety communication
None
From same serie
We use cookies to enhance your experience.