Technical specifications
Rated control supply voltage Us at AC 50HZ
- - -V
Rated control supply voltage Us at AC 60HZ
- - -V
Number of protected semiconductor outputs
2
Number of contact energized outputs with signalling function
0
Type of switching output of the OSSD
PNP/PNP
Operation agent-safety class
Safety class 3
Width sensor
29.4mm
Length of sensor
31mm
Fade-out possible
No
Detection capability for test bodies
0mm
Cascadable
No
Number of protected contact energized outputs
0
Ambient temperature
-10 - 55°C
Scope of delivery of the one-way system
Transmitter and receiver
Max. output current at protected output
400mA
Type of interface for safety communication
Other
Explosion safety category for dust
None
Resolution of the light curtain
0mm
Response time
3ms
Override possible
No
Transmission range of the safety field
12m
Switching voltage of OSSD at state "high"
24V
Safety field height
810mm
Rated control supply voltage Us at DC
24 - 24V
With monitoring function downstream switching devices
No
With muting function
Yes
Type of safety according to IEC 61496-1
4
Number of semiconductor outputs with signalling function
0
Height of sensor
977mm
Type of electric connection
Connector M12
Explosion safety category for gas
None
Reduced resolution
Yes
Voltage type
AC/DC
With beam coding
No
Wavelength of the sensor
950nm
Suitable for safety functions
Yes
Degree of protection (IP)
IP65
With restart blockage
Yes
Clock control possible
No
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XUSL4E3BB081N

Details
- Sensors
- Light curtain
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at AC 50HZ
- .. -V
Rated control supply voltage Us at AC 60HZ
- .. -V
Number of protected semiconductor outputs
2
Number of contact energized outputs with signalling function
0
Type of switching output of the OSSD
PNP/PNP
Operation agent-safety class
Safety class 3
Width sensor
29.4mm
Length of sensor
31mm
Fade-out possible
Detection capability for test bodies
0mm
Cascadable
Number of protected contact energized outputs
0
Ambient temperature
-10 .. 55°C
Scope of delivery of the one-way system
Transmitter and receiver
Max. output current at protected output
400mA
Type of interface for safety communication
Other
Explosion safety category for dust
None
Resolution of the light curtain
0mm
Response time
3ms
Override possible
Transmission range of the safety field
12m
Switching voltage of OSSD at state "high"
24V
Safety field height
810mm
Rated control supply voltage Us at DC
24 .. 24V
With monitoring function downstream switching devices
With muting function
Type of safety according to IEC 61496-1
4
Number of semiconductor outputs with signalling function
0
Height of sensor
977mm
Type of electric connection
Connector M12
Explosion safety category for gas
None
Reduced resolution
Voltage type
AC/DC
With beam coding
Wavelength of the sensor
950nm
Suitable for safety functions
Degree of protection (IP)
IP65
With restart blockage
Clock control possible
From same serie