Aleta.hr

Details

  • Sensors
  • Retroreflective photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Diameter sensor

-mm

Transmission range of the safety field

-m

Wavelength of the sensor

-nm

Switching voltage of OSSD at state "high"

-V

Light dot

-mm²

With time function

No

Pre failure notice

No

Rated switching distance

7000mm

Max. switching distance

10000mm

With reflector

Yes

Analogue output 4 mA ... 20 mA

No

Max. output current

3000mA

With communication interface analogue

No

With communication interface AS-Interface

No

With other analogue output

No

With communication interface DeviceNet

No

Analogue output 0 V ... 10 V

No

Analogue output -10 V ... +10 V

No

Setting procedure

Teach-In

Analogue output 0 mA ... 20 mA

No

With communication interface Ethernet

No

With communication interface PROFIBUS

No

With communication interface INTERBUS

No

With communication interface CANOpen

No

With monitoring function downstream switching devices

No

Rated control supply voltage Us at DC

24 - 240V

Laser protection class

None

Voltage type

AC/DC

With restart blockage

No

Type of light

Infrared light

Degree of protection (IP)

IP65

Suitable for safety functions

No

With communication interface SSI

No

With communication interface SSD

No

Number of protected contact energized outputs

0

Number of semiconductor outputs with signalling function

1

Number of protected semiconductor outputs

0

With communication interface RS-485

No

With communication interface RS-422

No

Type of switching output

Relay contact

Length of sensor

50mm

Height of sensor

50mm

Number of contact energized outputs with signalling function

0

Operation agent-safety class

Safety class 0

Type of switch function

Change-over contact (NO/NC)

Type of interface for safety communication

Other

Explosion safety category for gas

None

Explosion safety category for dust

None

Min. reflector distance

5000mm

Max. output current at protected output

3000mA

Sensing mode

Light switching

Type of safety according to IEC 61496-1

1

Width sensor

18mm

Material of optical surface

Plastic

Response time

25ms

Ambient temperature

-25 - 55°C

Rated control supply voltage Us at AC 50HZ

24 - 240V

Construction type housing

Cuboid

Material housing

Plastic

Switching frequency

20Hz

With communication interface RS-232

No

Rated control supply voltage Us at AC 60HZ

24 - 240V

Type of electric connection

Cable radial


Warehouse states

Zagreb:

0 pcs

Zadar:

0 pcs


From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.

XUK1ARCNL2H60

Main Product Image

Details

  • Sensors
  • Retroreflective photoelectric sensor
  • 1 KOM
  • SCHNEIDER

Technical specifications

Diameter sensor

-mm

Transmission range of the safety field

-m

Wavelength of the sensor

-nm

Switching voltage of OSSD at state "high"

-V

Light dot

-mm²

With time function

Pre failure notice

Rated switching distance

7000mm

Max. switching distance

10000mm

With reflector

Analogue output 4 mA ... 20 mA

Max. output current

3000mA

With communication interface analogue

With communication interface AS-Interface

With other analogue output

With communication interface DeviceNet

Analogue output 0 V ... 10 V

Analogue output -10 V ... +10 V

Setting procedure

Teach-In

Analogue output 0 mA ... 20 mA

With communication interface Ethernet

With communication interface PROFIBUS

With communication interface INTERBUS

With communication interface CANOpen

With monitoring function downstream switching devices

Rated control supply voltage Us at DC

24 .. 240V

Laser protection class

None

Voltage type

AC/DC

With restart blockage

Type of light

Infrared light

Degree of protection (IP)

IP65

Suitable for safety functions

With communication interface SSI

With communication interface SSD

Number of protected contact energized outputs

0

Number of semiconductor outputs with signalling function

1

Number of protected semiconductor outputs

0

With communication interface RS-485

With communication interface RS-422

Type of switching output

Relay contact

Length of sensor

50mm

Height of sensor

50mm

Number of contact energized outputs with signalling function

0

Operation agent-safety class

Safety class 0

Type of switch function

Change-over contact (NO/NC)

Type of interface for safety communication

Other

Explosion safety category for gas

None

Explosion safety category for dust

None

Min. reflector distance

5000mm

Max. output current at protected output

3000mA

Sensing mode

Light switching

Type of safety according to IEC 61496-1

1

Width sensor

18mm

Material of optical surface

Plastic

Response time

25ms

Ambient temperature

-25 .. 55°C

Rated control supply voltage Us at AC 50HZ

24 .. 240V

Construction type housing

Cuboid

Material housing

Plastic

Switching frequency

20Hz

With communication interface RS-232

Rated control supply voltage Us at AC 60HZ

24 .. 240V

Type of electric connection

Cable radial

From same serie

*VPC is wholesale amount without VAT (tax on added value). For wholesale discounts, please register as business user.