Details
- Sensors
- Retroreflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
-mm
Transmission range of the safety field
-m
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Light dot
-mm²
With time function
No
Pre failure notice
No
Rated switching distance
7000mm
Max. switching distance
10000mm
With reflector
Yes
Analogue output 4 mA ... 20 mA
No
Max. output current
3000mA
With communication interface analogue
No
With communication interface AS-Interface
No
With other analogue output
No
With communication interface DeviceNet
No
Analogue output 0 V ... 10 V
No
Analogue output -10 V ... +10 V
No
Setting procedure
Teach-In
Analogue output 0 mA ... 20 mA
No
With communication interface Ethernet
No
With communication interface PROFIBUS
No
With communication interface INTERBUS
No
With communication interface CANOpen
No
With monitoring function downstream switching devices
No
Rated control supply voltage Us at DC
24 - 240V
Laser protection class
None
Voltage type
AC/DC
With restart blockage
No
Type of light
Infrared light
Degree of protection (IP)
IP65
Suitable for safety functions
No
With communication interface SSI
No
With communication interface SSD
No
Number of protected contact energized outputs
0
Number of semiconductor outputs with signalling function
1
Number of protected semiconductor outputs
0
With communication interface RS-485
No
With communication interface RS-422
No
Type of switching output
Relay contact
Length of sensor
50mm
Height of sensor
50mm
Number of contact energized outputs with signalling function
0
Operation agent-safety class
Safety class 0
Type of switch function
Change-over contact (NO/NC)
Type of interface for safety communication
Other
Explosion safety category for gas
None
Explosion safety category for dust
None
Min. reflector distance
5000mm
Max. output current at protected output
3000mA
Sensing mode
Light switching
Type of safety according to IEC 61496-1
1
Width sensor
18mm
Material of optical surface
Plastic
Response time
25ms
Ambient temperature
-25 - 55°C
Rated control supply voltage Us at AC 50HZ
24 - 240V
Construction type housing
Cuboid
Material housing
Plastic
Switching frequency
20Hz
With communication interface RS-232
No
Rated control supply voltage Us at AC 60HZ
24 - 240V
Type of electric connection
Cable radial
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XUK1ARCNL2H60
Details
- Sensors
- Retroreflective photoelectric sensor
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
-mm
Transmission range of the safety field
-m
Wavelength of the sensor
-nm
Switching voltage of OSSD at state "high"
-V
Light dot
-mm²
With time function
Pre failure notice
Rated switching distance
7000mm
Max. switching distance
10000mm
With reflector
Analogue output 4 mA ... 20 mA
Max. output current
3000mA
With communication interface analogue
With communication interface AS-Interface
With other analogue output
With communication interface DeviceNet
Analogue output 0 V ... 10 V
Analogue output -10 V ... +10 V
Setting procedure
Teach-In
Analogue output 0 mA ... 20 mA
With communication interface Ethernet
With communication interface PROFIBUS
With communication interface INTERBUS
With communication interface CANOpen
With monitoring function downstream switching devices
Rated control supply voltage Us at DC
24 .. 240V
Laser protection class
None
Voltage type
AC/DC
With restart blockage
Type of light
Infrared light
Degree of protection (IP)
IP65
Suitable for safety functions
With communication interface SSI
With communication interface SSD
Number of protected contact energized outputs
0
Number of semiconductor outputs with signalling function
1
Number of protected semiconductor outputs
0
With communication interface RS-485
With communication interface RS-422
Type of switching output
Relay contact
Length of sensor
50mm
Height of sensor
50mm
Number of contact energized outputs with signalling function
0
Operation agent-safety class
Safety class 0
Type of switch function
Change-over contact (NO/NC)
Type of interface for safety communication
Other
Explosion safety category for gas
None
Explosion safety category for dust
None
Min. reflector distance
5000mm
Max. output current at protected output
3000mA
Sensing mode
Light switching
Type of safety according to IEC 61496-1
1
Width sensor
18mm
Material of optical surface
Plastic
Response time
25ms
Ambient temperature
-25 .. 55°C
Rated control supply voltage Us at AC 50HZ
24 .. 240V
Construction type housing
Cuboid
Material housing
Plastic
Switching frequency
20Hz
With communication interface RS-232
Rated control supply voltage Us at AC 60HZ
24 .. 240V
Type of electric connection
Cable radial
From same serie
We use cookies to enhance your experience.