Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Voltage type
AC/DC
Material housing
Plastic
Rated control supply voltage Us at DC
12 - 24V
Type of electric connection
Cable radial
Explosion safety category for dust
None
Length of sensor
52.6mm
Type of interface
None
Construction type housing
Cylinder, screw-thread
Diameter sensor
30mm
Type of interface for safety communication
None
Coating housing
Other
SIL according to IEC 61508
None
With monitoring function downstream switching devices
No
Number of protected semiconductor outputs
0
Supply voltage
12 - 24V
Number of contact energized outputs with signalling function
0
Category according to EN 954-1
1
Type of switching output
Two-wire
Type of switch function
Breaker contact
Number of semiconductor outputs with signalling function
1
Switching frequency
300Hz
Suitable for safety functions
No
Number of protected contact energized outputs
0
Explosion safety category for gas
None
Performance level according to EN ISO 13849-1
None
Max. output current at protected output
200mA
Compression-resistant
No
Mechanical mounting condition for sensor
Not flat
Interference resistance to magnetic fields
Immune against magnetic DC-field
Cascadable
No
Switching distance
15mm
Type of actuation
Metallic Target
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XS4P30AB120L1

Details
- Sensors
- Inductive proximity switch
- 1 KOM
- SCHNEIDER
Technical specifications
Voltage type
AC/DC
Material housing
Plastic
Rated control supply voltage Us at DC
12 .. 24V
Type of electric connection
Cable radial
Explosion safety category for dust
None
Length of sensor
52.6mm
Type of interface
None
Construction type housing
Cylinder, screw-thread
Diameter sensor
30mm
Type of interface for safety communication
None
Coating housing
Other
SIL according to IEC 61508
None
With monitoring function downstream switching devices
Number of protected semiconductor outputs
0
Supply voltage
12 .. 24V
Number of contact energized outputs with signalling function
0
Category according to EN 954-1
1
Type of switching output
Two-wire
Type of switch function
Breaker contact
Number of semiconductor outputs with signalling function
1
Switching frequency
300Hz
Suitable for safety functions
Number of protected contact energized outputs
0
Explosion safety category for gas
None
Performance level according to EN ISO 13849-1
None
Max. output current at protected output
200mA
Compression-resistant
Mechanical mounting condition for sensor
Not flat
Interference resistance to magnetic fields
Immune against magnetic DC-field
Cascadable
Switching distance
15mm
Type of actuation
Metallic Target
From same serie