- Relays
- Device for monitoring of safety-related circuits
- 1 KOM
- SCHNEIDER
Technical specifications
Release-delay
- - -s
Model
Expansion device
Rated control supply voltage Us at DC
24 - 24V
Suitable for monitoring of emergency-stop circuits
Yes
Voltage type for actuating
DC
Suitable for monitoring of position switches
Yes
Suitable for monitoring of valves
No
Suitable for monitoring of optoelectronic protection equipment
Yes
Suitable for monitoring of proximity switches
Yes
Evaluation inputs
Other
Number of outputs, safety related, delayed, semiconductors
0
With start input
Yes
Type of electric connection
Screw connection
Number of outputs, safety related, undelayed, with contact
0
With muting function
Yes
With detachable clamps
Yes
Number of outputs, signalling function, delayed, semiconductors
0
Rail mounting possible
Yes
Number of outputs, safety related, undelayed, semiconductors
0
Number of outputs, signalling function, undelayed, with contact
0
Suitable for monitoring of tactile sensors
Yes
Type of safety according to IEC 61496-1
4
Stop category according to IEC 60204
0 + 1
SIL according to IEC 61508
3
Suitable for monitoring of magnetic switches
Yes
Number of outputs, signalling function, undelayed, semiconductors
0
Height
99mm
With approval for BG BIA
No
Number of outputs, safety related, delayed, with contact
0
Number of outputs, signalling function, delayed, with contact
0
With approval according to UL
Yes
Performance level according to EN ISO 13849-1
Level e
With approval for TÜV
Yes
With feedback circuit
Yes
Width
22.5mm
Depth
114.5mm
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XPSMCMDI1600

Details
- Relays
- Device for monitoring of safety-related circuits
- 1 KOM
- SCHNEIDER
Technical specifications
Release-delay
- .. -s
Model
Expansion device
Rated control supply voltage Us at DC
24 .. 24V
Suitable for monitoring of emergency-stop circuits
Voltage type for actuating
DC
Suitable for monitoring of position switches
Suitable for monitoring of valves
Suitable for monitoring of optoelectronic protection equipment
Suitable for monitoring of proximity switches
Evaluation inputs
Other
Number of outputs, safety related, delayed, semiconductors
0
With start input
Type of electric connection
Screw connection
Number of outputs, safety related, undelayed, with contact
0
With muting function
With detachable clamps
Number of outputs, signalling function, delayed, semiconductors
0
Rail mounting possible
Number of outputs, safety related, undelayed, semiconductors
0
Number of outputs, signalling function, undelayed, with contact
0
Suitable for monitoring of tactile sensors
Type of safety according to IEC 61496-1
4
Stop category according to IEC 60204
0 + 1
SIL according to IEC 61508
3
Suitable for monitoring of magnetic switches
Number of outputs, signalling function, undelayed, semiconductors
0
Height
99mm
With approval for BG BIA
Number of outputs, safety related, delayed, with contact
0
Number of outputs, signalling function, delayed, with contact
0
With approval according to UL
Performance level according to EN ISO 13849-1
Level e
With approval for TÜV
With feedback circuit
Width
22.5mm
Depth
114.5mm