Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50041
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 230 V
3A
Rated operation current Ie at DC-13, 230 V
0.27A
Height of sensor
77mm
Switching function latching
No
Output electronic
No
Forced opening
No
Number of safety auxiliary contacts
0
Switching function
Quick-break switch
Length of sensor
44mm
Width sensor
40mm
Number of contacts as normally closed contact
1
Material housing
Metal
Type of interface
None
Alignment of the control element
Other
Suitable for safety functions
No
Type of control element
Actuating rod
Coating housing
Other
Type of electric connection
Other
With status indication
No
Explosion safety category for gas
None
Construction type housing
Cuboid
Number of contacts as change-over contact
0
Ambient temperature during operating
-25 - 70°C
Degree of protection (IP)
IP66/IP67
Type of interface for safety communication
None
Number of contacts as normally open contact
1
Explosion safety category for dust
None
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
XCKJ10553H7

Details
- Sensors
- End switch
- 1 KOM
- SCHNEIDER
Technical specifications
Diameter sensor
0mm
Rated operation current Ie at DC-13, 24 V
0A
Rated operation current Ie at AC-15, 24 V
0A
Housing according to norm
DIN EN 50041
Rated operation current Ie at AC-15, 125 V
0A
Rated operation current Ie at DC-13, 125 V
0A
Rated operation current Ie at AC-15, 230 V
3A
Rated operation current Ie at DC-13, 230 V
0.27A
Height of sensor
77mm
Switching function latching
Output electronic
Forced opening
Number of safety auxiliary contacts
0
Switching function
Quick-break switch
Length of sensor
44mm
Width sensor
40mm
Number of contacts as normally closed contact
1
Material housing
Metal
Type of interface
None
Alignment of the control element
Other
Suitable for safety functions
Type of control element
Actuating rod
Coating housing
Other
Type of electric connection
Other
With status indication
Explosion safety category for gas
None
Construction type housing
Cuboid
Number of contacts as change-over contact
0
Ambient temperature during operating
-25 .. 70°C
Degree of protection (IP)
IP66/IP67
Type of interface for safety communication
None
Number of contacts as normally open contact
1
Explosion safety category for dust
None
From same serie