Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- - -V
Rated power, 460 V, 60 Hz, 3-phase
-kW
Rated operation power at AC-3, 230 V, 3-phase
-kW
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
With short-circuit release
Yes
Type of motor starter
Direct online starter (DOL)
Rated operation current Ie
4A
Rated operation power at AC-3, 400 V
1.5kW
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated operation current at AC-3, 400 V
4A
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
2.5 - 4A
Temperature compensated overload protection
Yes
Type of electrical connection of main circuit
Screw connection
Ambient temperature, upper operating limit
40°C
Rated control supply voltage Us at AC 50HZ
24 - 24V
Type of electrical connection for auxiliary- and control current circuit
Screw connection
With transformer
Yes
Rail mounting possible
No
Number of command positions
4
Coordination class according to IEC 60947-4-3
Class 1
With fuse
No
Suitable for emergency stop
Yes
Voltage type for actuating
AC
Supporting protocol for TCP/IP
No
External reset possible
No
Number of indicator lights
0
Release class
CLASS 10
Supporting protocol for DeviceNet
No
Degree of protection (IP)
IP55
Supporting protocol for ASI
No
Supporting protocol for CAN
No
Supporting protocol for Data-Highway
No
Supporting protocol for EtherNet/IP
No
Number of auxiliary contacts as normally open contact
0
Supporting protocol for PROFINET CBA
No
Supporting protocol for PROFINET IO
No
Supporting protocol for INTERBUS
No
Supporting protocol for LON
No
Supporting protocol for SUCONET
No
Supporting protocol for INTERBUS-Safety
No
Supporting protocol for SERCOS
No
Supporting protocol for Foundation Fieldbus
No
Supporting protocol for PROFIsafe
No
Supporting protocol for AS-Interface Safety at Work
No
Supporting protocol for other bus systems
No
Supporting protocol for SafetyBUS p
No
Width
175mm
Height
165mm
Depth
177mm
Supporting protocol for Modbus
No
Supporting protocol for DeviceNet Safety
No
Supporting protocol for PROFIBUS
No
Rated control supply voltage Us at AC 60HZ
24 - 24V
Warehouse states
Zagreb:
0 pcs
Zadar:
0 pcs
From same serie
LJ7K06Q708

Details
- Low-voltage industrial components
- Motor starter/Motor starter combination
- 1 KOM
- SCHNEIDER
Technical specifications
Rated control supply voltage Us at DC
- .. -V
Rated power, 460 V, 60 Hz, 3-phase
-kW
Rated operation power at AC-3, 230 V, 3-phase
-kW
Rated power, 575 V, 60 Hz, 3-phase
-kW
Rated conditional short-circuit current, type 1, 480 Y/277 V
-A
Rated conditional short-circuit current, type 1, 600 Y/347 V
-A
Rated conditional short-circuit current, type 2, 230 V
-A
With short-circuit release
Type of motor starter
Direct online starter (DOL)
Rated operation current Ie
4A
Rated operation power at AC-3, 400 V
1.5kW
Rated conditional short-circuit current, type 2, 400 V
50000A
Rated operation current at AC-3, 400 V
4A
Number of auxiliary contacts as normally closed contact
0
Overload release current setting
2.5 .. 4A
Temperature compensated overload protection
Type of electrical connection of main circuit
Screw connection
Ambient temperature, upper operating limit
40°C
Rated control supply voltage Us at AC 50HZ
24 .. 24V
Type of electrical connection for auxiliary- and control current circuit
Screw connection
With transformer
Rail mounting possible
Number of command positions
4
Coordination class according to IEC 60947-4-3
Class 1
With fuse
Suitable for emergency stop
Voltage type for actuating
AC
Supporting protocol for TCP/IP
External reset possible
Number of indicator lights
0
Release class
CLASS 10
Supporting protocol for DeviceNet
Degree of protection (IP)
IP55
Supporting protocol for ASI
Supporting protocol for CAN
Supporting protocol for Data-Highway
Supporting protocol for EtherNet/IP
Number of auxiliary contacts as normally open contact
0
Supporting protocol for PROFINET CBA
Supporting protocol for PROFINET IO
Supporting protocol for INTERBUS
Supporting protocol for LON
Supporting protocol for SUCONET
Supporting protocol for INTERBUS-Safety
Supporting protocol for SERCOS
Supporting protocol for Foundation Fieldbus
Supporting protocol for PROFIsafe
Supporting protocol for AS-Interface Safety at Work
Supporting protocol for other bus systems
Supporting protocol for SafetyBUS p
Width
175mm
Height
165mm
Depth
177mm
Supporting protocol for Modbus
Supporting protocol for DeviceNet Safety
Supporting protocol for PROFIBUS
Rated control supply voltage Us at AC 60HZ
24 .. 24V
From same serie